someone's desk (so as not to disturb that individual). To completely turn off the
sounder perform the following. Put your Digital Keypad into the Programming
mode by either pushing the PRGM CODE push button on the CPU (see figure 2) or
by entering your Program Code (See section on Program Code if you do not have
one loaded in your Digital Keypad) on the keypad. Once the Yellow LED begins to
flash, tap in code 71. Wait a few seconds for the Red LED (Green if using Reverse
Light Logic) to flash twice. The Yellow LED will resume flashing. Simply press the
Bell Key (or * or # on the DK-16) to end the programming mode.
Press a couple
of keys to verify that the sounder has been silenced.
TO SOUND THE SOUNDER WHILE THE DOOR IS UNLOCKED – You can alternately
select to have the sounder emit a tone during the entire time that the door is
unlocked. To implement this option follow the following procedure. Put your Digital
Keypad into the Programming mode by either pushing the PRGM CODE push button
on the CPU (see figure 2) or by entering your Program Code (See section on
Program Code if you do not have one loaded in your Digital Keypad) on the keypad.
Once the Yellow LED begins to flash, tap in code 70. Wait a few seconds for the
Red LED (Green if using Reverse Light Logic) to flash twice. The Yellow LED will
resume flashing. Simply press the Bell Key (or * or # on the DK-16) to end the
programming mode. Enter one of your User Codes or the Hard Code to verify that
when the door unlocks you get the tone for entire unlock duration.
TO RETURN SOUNDER TO FACTORY SETTING – If you wish to return the sounder to
the factory default perform the following sequence. Put your Digital Keypad into
the Programming mode by either pushing the PRGM CODE push button on the CPU
(see figure 2) or by entering your Program Code (See section on Program Code if
you do not have one loaded in your Digital Keypad) on the keypad. Once the
Yellow LED begins to flash, tap in code 72. Wait a few seconds for the Red LED
(Green if using Reverse Light Logic) to flash twice. The Yellow LED will resume
flashing. Simply press the Bell Key (or * or # on the DK-16) to end the
programming mode. Enter one of your User Codes or the Hard Code to verify that
the sounder only echoes the keystrokes.

SECTION 13 - SUMMARY

The above information will give you the basics of operating your Digital Keypad.
There are several other functions available, but most of these require a technician
to rewire the components. If you need your system to perform a function not listed
please contact Securitron Technical Support, and we will work with you to see if it
can be implemented.
Released: 8/27/2009