You can set all the parameters of the amplifiers through the 6105A user interface. Refer
to the 6105A Users Manual to learn more.
You can supply a maximum of 360 amps when you connect three Products to a 6105A or
6100B and connect the outputs in parallel. The amplitude and phase angle accuracy
specifications for three Products in parallel are the same as for the Product.

Multi-Phase Current Outputs

For mutli-phase current output, use a 6105A for one phase and a 6106A for all other
phases. The 6105A controls all 6106As. One Product is necessary for each phase angle.
To set up a three-phase output:
1. Connect a control cable between the L2 Control Output connector of the 6105A and
the Auxiliary Control Input connector of a 6106A.
2. Connect a second control cable between the L3 Control Output connector of the
6105A and the Auxiliary Control Input connector of a second 6106A. See Figure 2-9.
Front-Panel Operation
How to Setup Multiple Amplifiers