• When the length of the wiring is less than 5 m (approximate)
Remove the shorting bar 1 or the shorting bar 2 and connect the terminal (#1/#2 or #3/#4) to the contact.
- An external power supply is not necessary.
- A maximum of 2 sets of contacts can be connected (when both the shorting bar 1 and the shorting bar 2 are
removed.)
- The minimum rating for the contact is as below.
Voltage
5V or less
• When the length of the wiring is at least 5 m (approximate)
Remove the shorting bar 1 and the shorting bar 2 and connect an external power supply and the contact to the ter-
minals (#2 and #3) in series (do not use #1 and #4.)
- Connect #2 to the positive side of an external power supply, and connect #3 to the negative side of the external
power supply.
- The voltage for the connecting external power supply should be within a range of 5V minimum to 16V maximum.
The minimum rating for the contact depends on the voltage of the external power supply.
Voltage
5V
16V
Minimum rated current
2mA or less
Minimum rated current
2mA
18mA