OPERATION
This gas combination gives good cut speed, low dross levels and is very economical. Some surface
nitriting and surface oxidation of alloying elements can occur.
020424
Shield
English
Plasma Gas
Pressure
Plasma
Gas
Flowrate
Test
Run
(SCFH)
(psi)
(psi)
66
44-48
58-62
Metric
Plasma Gas
Pressure
Plasma
Gas
Flowrate
Test
Run
(l/min)
(bar)
(bar)
31
3.0-3.3 4.0-4.3
Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 7/8 inch (21 mm) not recommended.
4-38
15
Stainless Steel – 3" Under Water
•
200 amps
020423
Retaining cap
Shield
Gas
Material
Shield
Pressure
Thickness
Gas
Flowrate
(psi)
(Inches)
(SCFH)
3/16
1/4
3/8
1/2
280
70
5/8
3/4
7/8
Shield
Gas
Material
Shield
Pressure
Thickness
Gas
Flowrate
(bar)
(mm)
(l/min)
10
132
4.8
12
15
20
25
Air Plasma / Air Shield
020608
020607
Nozzle
Swirl ring
Torch-to-Work
Distance
(Inches)
(mm)
1/8
3
1/8
3
1/8
3
1/8
3
.16
4
3/16
5
1/4
6
1
1/4
6
Torch-to-Work
Distance
(mm)
(Inches)
3
1/8
5
3
1/8
6
3
1/8
3
1/8
4
.16
5
3/16
6
1/4
220021
Electrode
Arc
Voltage
Setting
Travel Speed
(Volts)
(ipm)
(mm/min)
125
210
5320
130
180
4500
135
125
3150
140
90
2300
145
60
1520
145
45
1150
150
30
750
155
22
570
Arc
Voltage
Setting
Travel Speed
(Volts)
(mm/min)
(ipm)
125
5320
210
130
4500
180
135
3150
125
140
2300
90
145
1520
60
145
1150
45
155
570
22
MAX200 Instruction Manual
Approx.
Motion
Delay Time
(sec)
0.0
0.5
1.0
2.0
2.0
2.5
3.0
*
Approx.
Motion
Delay Time
(sec)
0.0
0.5
1.0
2.0
2.0
2.5
*
Need help?
Do you have a question about the MAX200 and is the answer not in the manual?