Service Parts List - Hearth and Home Technologies PVK-80 Installation Instructions Manual

Power vent
Table of Contents

Advertisement

4. Remove any cover or plate protecting valve and
module wiring assembly or switch.
5. Unplug two brown wires on the green module and
plug into red and brown wires from wiring harness
terminal block.
Figure 7.
Note: Electrical service of 120 VAC-60Hz must be supplied
to the junction box of the fi replace in order for the power vent
to operate correctly.

Service Parts List

Description
Power Vent Cap Assembly
Blower Power Vent
Vacuum Switch
Wire Harness Water Proof
Power Vent Support Bottom
Power Vent Support Top
Wire Harness
10" Wire Assembly
Firestop
Hardware Bag
4
Part Number
2026-018
655-500
655-522
655-531A
655-100
655-101
2065-112
2065-114
2045-006
655-900A
Heat & Glo • PVK-80 Power Vent Instructions • 655-900 Rev. O • 12/09
6. Plug one end of the black wire harness into one
of the HOT terminals on the junction box. Plug
the other female end into the back of the rocker
switch, where the brown wires were removed in
Step 6.
7. Plug the white wire from the terminal block har-
ness into one of the NEUTRAL terminals of the
junction box.
8. Plug the black wire from the terminal block har-
ness into the back of the rocker switch.
WARNING: ON/OFF switch and remote wires are
high voltage (120 VAC). Use proper wire.
9. Attach terminal block to base of fi replace using
Velcro pads provided.
10. Remove battery box unplugging red and black
wires. (Battery backup will not work with PVK-80
installed.)
11. Replace any covers or plates removed in Step B.
12. Cable tie the wires together so that no wire is in
contact with the top of the cavity under the fi re-
place.
13. Reconnect electrical power supply to the junction
box.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents