LEFT LIMIT
Move the frame right/left using the right/left keys on the keyboard.
TOP LIMIT
Shift the frame up/down using the right/left keys on the keyboard.
H/V SIZE
Adjust the frame size via changing H/V size value using the right/left keys on the
keyboard.
MODE
Assign a trigger action for a motion detection frame. Options include PRESET,
SEQUENCE, AUTOPAN and CRUISE. When motion is detected within a frame, the
Dome Camera will execute the specific trigger action.
DWELL TIME
The DWELL TIME is duration of executing a trigger action. If select the PRESET mode,
when motion is detected, the Dome Camera will go to the selected Preset position and
stay there for a user-defined period of time (1~127 seconds/Always). If select other
modes (SEQUENCE/ /AUTOPAN /CRUISE), the Dome Camera will keep executing the
selected mode (DWELL TIME: ALWAYS) until it is interrupted by commands sent from
a connected control device.
EXIT
Exit the FRAME setting page and return to the ALARM DETECT main page.
FRAME DISABLE
Select a frame to be canceled, and press "ENTER." The selected frame will then be removed
from the monitored field.
THRESHOLD
The Threshold range is adjustable from 1~255. The smaller the value, the more sensitive it is;
i.e. 1: highest sensitivity; 255: lowest sensitivity.
EXIT
Exit the ALARM DETECT menu and return to the MAIN PAGE.