VIDEO PLUS AHP-3112S User Manual

12x outdoor ptz dome camera

Advertisement

Quick Links

AHP-3112S
12x Outdoor PTZ Dome Camera

User Manual

Advertisement

Table of Contents
loading

Summary of Contents for VIDEO PLUS AHP-3112S

  • Page 1: User Manual

    AHP-3112S 12x Outdoor PTZ Dome Camera User Manual...
  • Page 2: Safety Warning

    Safety Warning GVI Security, Inc. reserves the right to revise and improve its products. All specifications are subject to change without notice. Notice To work with the PTZ Dome Cameras, any installer or technician must have the following minimum qualifications: A basic knowledge of CCTV systems and components A basic knowledge of electrical wiring and low-voltage electrical hookups A basic knowledge of network system setting...
  • Page 3: Safety Information

    Safety Information Retain and follow all safety and operating instructions. Observe all warnings on products. Unplug the product from the electrical outlet and discontinue use under the following conditions: The power cord or plug is damaged; the product is exposed to liquid; the product is dropped or an object falls on the product; the product is noticeably overheated.
  • Page 4: Table Of Contents

    Table of Contents 1. O ..................................5 VERVIEW 1.1 Product Features ..............................5 1.2 Product Application ............................6 2. C PTZ D ........................7 ONNECTING THE AMERA 2.1 Package Content ..............................7 2.2 Switch/Connector Definition .......................... 7 2.3 Communication Switch Setting ........................8 2.4 ID Setup ................................
  • Page 5: Overview

    I. Overview The PTZ Dome Camera is an innovative Speed Dome Camera designed for small to medium sized surveillance applications and possesses true speed dome camera features, such as high speed and accurate Pan/Tilt, up to 144x zoom ratio (12x optical, and 12x digital zoom), 180° Digital Image Flip, Proportional Zoom, and Preset Speed up to 400°/s.
  • Page 6: Product Application

    Product Application Connect Dome Cameras to other devices, as shown in the diagram, to complete a video surveillance solution. NOTE: To extend the network distance up to 1.2 km (4000 feet) and to protect the connected devices, it is highly recommended to use a repeater at the mid-point. However, a repeater may be needed in the network distance less than 1.2 km if the used cables are not the CAT 5, 24-gauge cables.
  • Page 7: Connecting The Ptz Dome Camera

    2. Connecting the PTZ Dome Camera Please refer to the following sections to connect, set and operate the PTZ Dome Camera. In order to control the camera, basically a control keyboard or other control device is required. Package Content Before proceeding, ensure that the contents match the items listed below. If any item is missing or has defects, DO NOT install or operate the product and contact the dealer for assistance.
  • Page 8: Communication Switch Setting

    The ID and Protocol numbers of the Dome Camera are set with a 10-bit and 6-bit dip switch respectively using binary system. For switch configuration details, please refer to Appendix B: Switch Settings Index Table. 2.3 Communication Switch Setting The Dome Camera’s communication switches are specified in the table below. Communication Switch SW 1 RS-485 Setting...
  • Page 9 RS-485 Setting Half-duplex Full-duplex The Full-duplex setting leads transmission of data in two directions simultaneously. To complete the setting, refer to 2.7 RS-485 Connector Definition. GVI Security...
  • Page 10: Id Setup

    2.4 ID Setup Change the analog Dome Camera’s ID if there is more than one Dome Camera in the same network. Use the switch to change the PTZ Dome Camera’s ID by setting the 10-bit dip switch. For instance, if the camera’s ID is 006, set the SW-2 and SW-3 to “ON,”...
  • Page 11: 22-Pin Connector Definition

    2.6 22-Pin Connector Definition An AC 24V Data Cable ships with the integrated high speed PTZ Dome for quick installation for demo or testing usage. See the diagrams below for more information. The Dome Camera’s 22-pin connector definition is specified in the latter part. The PTZ Dome Camera’s Data Cables are illustrated as shown below: AC24V Data Cable: NOTE: Be careful not to pull the cables improperly during installation.
  • Page 12: Rs-485 Connector Definition

    The Dome Camera’s 22-pin connector definition is listed as shown below. Definition Cable Definition Cable 20AWG/18AWG ALM-1 AC 24-1/DC (+) ALM NC ALM-3 20AWG/18AWG ALM-2 AC 24-2/DC (-) ALM NO ALM-4 20AWG/18AWG ALM-5 ALM COM ALM-6 ALM-7 ALM-8 24AWG ALM GND VGND 20AWG ISOG...
  • Page 13: Operation And Configuration

    Operation and Configuration OSD Display Format Information shown on the screen is described in terms of OSD display, position, and function description as shown in the table below. Position Function OSD Display Description Auto Focus Mode Focus Modes Manual Focus Mode Back Light Compensation OFF Backlight Back Light Compensation ON...
  • Page 14 Item Layer 1 Layer 2 Layer 3 Default NTSC: <1/60> ~ <1/10000> SEC. IRIS VALUE <F1.6> GAIN VALUE <-3>dB ~ <28>dB EXIT + SAVE: YES EXIT+ SAVE: THRESHOLD <MID>, <HI>, <LOW> AUTO EXIT + SAVE: YES AUTO FUNCTION IR MANUAL: <ON>, <OFF> MANUAL EXIT + SAVE: YES BACKLIGHT...
  • Page 15 Item Layer 1 Layer 2 Layer 3 Default EXIT ENTER SEQUENCE LINE <1> ~ <8> SEQUENCE POINT <01> ~ <64> PRESET POS. <001> ~ <255>, <END> SEQUENCE ENTER SPEED <01> ~ <15> DWELL TIME <000> ~ <127> SEC. RUN SEQUNECE ENTER EXIT <YES>...
  • Page 16: Configuration Menu

    Item Layer 1 Layer 2 Layer 3 Default <BLACK>, <WHITE>, <RED>, <GREEN>, <BLUE>, COLOR <CYAN>, <YELLOW>,<MAGENTA> H CENTER: L/R V CENTER: D/U SET MASK <01> ~ <16> H SIZE <000> ~ <080> V SIZE <000> ~ <060> EXIT + SAVE CLEAR MASK <01>...
  • Page 17 3.3.1 Focus The Dome Camera’s focus can be operated in two modes: Manual Focus mode and Auto Focus mode. AUTO There are three options available for the AF Mode, including Normal mode, Zoom Trigger (Z. TRIG.) mode and PTZ Trigger (PTZ TRIG.) mode. The submenu of AF Mode is shown below: Normal Mode In this mode, the camera will keep in focus automatically and continuously in any condition.
  • Page 18 3.3.3 IR Function With the IR cut filter, the Dome Camera can still catch clear image at night time or in the very dark light condition. During day time, the IR cut filter will be on to block the infrared light for clear image; during night time or in dark light condition, the IR cut filter will be removed to catch infrared light, and the displayed images will become black and white.
  • Page 19: Wbc Mode

    3.3.5 WBC Mode A digital camera needs to find reference color temperature, which is a way of measuring the color of a light source, for calculating all the other colors. The unit for measuring this ratio is in degree Kelvin (K).
  • Page 20: Setup Menu

    3.3.7 Setup Menu 1 The SETUP MENU 1 is shown below. The zoom speed of the PTZ Dome Camera is fixed (Value: 8). Users could choose whether to activate functions including Digital Zoom, Slow Shutter, Noise Reduction, Image Inverse and Image Freeze. Refer to the following description for use of each function.
  • Page 21 FREEZE Freeze function allows holding the image while the camera is moving between preset positions such as in PRESET and SEQUENCE. For example, when the Dome Camera is manipulated to run from point A to point B, if the Freeze function is activated, the first view that users would see is point A.
  • Page 22: Angle Adjuster

    ANGLE ADJUSTER The item is for adjusting the camera view angle. The range of view angle is between -10 and+100. SPEED BY ZOOM If the item is set to <ON>, the pan/tilt speed will be adjusted by internal algorithm when zooming automatically.
  • Page 23: Default Camera

    NOTE: When turning the password on the first time, enter the Master Password to setup the new password. The Master Password is 9527. OSD AUTO CLOSE Users can specify the duration for OSD menu to stay on the screen. Time selection ranges from 5 ~ 30 seconds.
  • Page 24: Title Setting

    3.3.12 Title Setting Up to 16 zone titles can be set with maximum 20 characters for each title. Follow the steps to set a camera title. Operate the dome to a view area where you want to set a title for it. Turn on the OSD and go to the MAIN PAGE 2 to select <TITLE SETTING>.
  • Page 25 3.3.14 Sequence The function executes pre-positioning of the pan, tilt, zoom and focus features in a certain sequence for a camera. Before setting this function, users must preset at least two preset points. SEQUENCE LINE There are eight sets of sequence lines built in the Dome Camera. Using LEFT/RIGHT direction keys to select a line first and then set its sequence points.
  • Page 26 3.3.15 Auto-pan Auto-pan means motion of scanning an area horizontally so that the PTZ Dome Camera can capture events in horizontal view. The parameters are listed as follows. AUTOPAN LINE There are four sets of auto-pan line built in a PTZ Dome Camera. Users can choose a line to execute using LEFT/RIGHT direction keys.
  • Page 27 EXIT Exit the AUTOPAN setup menu and return to the MAIN PAGE. NOTE: Perform the auto-pan function through a PTZ keyboard controller. Please refer to the control keyboard’s quick guide for further information. 3.3.16 Cruise CRUISE is a route formed with manual operation, through adjusting pan and tilt position, which can be stored and recalled to execute repeatedly.
  • Page 28: Home Setting

    3.3.17 Home Setting Users are able to set an operation mode to ensure constant monitoring; if the Dome Camera idles for a period of time, the selected function will be activated automatically. HOME function allows constant and accurate monitoring to avoid the Dome Camera stopping or missing events. HOME FUNCTION The item is used to enable or disable the HOME function.
  • Page 29: Alarm Setting

    3.3.18 Alarm Setting The Mini Speed Dome provides eight alarm inputs and one alarm output (N.O. and N.C) to connect alarm devices. With this function, the Dome Camera will cooperate with alarm system to catch the event images. For wiring, please refer to the installation guide and/or qualified service personnel. Adjustable alarm parameters are listed below.
  • Page 30 SEQUENCE LINE Select a Sequence Line that the Dome Camera should execute when an alarm pin is triggered. The sequence line(s) should be defined prior either in the SEQUENCE setup menu or through the keyboard. AUTOPAN LINE Select an Auto-pan Line that the Dome Camera should execute when an alarm pin is triggered.
  • Page 31: Alarm Detect

    3.3.19 Alarm Detect When the Alarm Detect function is activated, the camera will detect movement within a monitoring area and then send an alarm signal automatically. There will be a flash warning notice: MOTION displayed in the upper left corner of the screen. DETECT SWITCH The item is used to enable or disable the ALARM DETECT function.
  • Page 32 LEFT LIMIT Move the frame right/left using the right/left keys on the keyboard. TOP LIMIT Shift the frame up/down using the right/left keys on the keyboard. H/V SIZE Adjust the frame size via changing H/V size value using the right/left keys on the keyboard.
  • Page 33: Privacy Mask

    3.3.20 Privacy Mask The Privacy Mask function aims to avoid any intrusive monitoring. Users can adjust the camera view position using the joystick, and adjust the mask size and area via the direction keys on the control keyboard. When setting a mask, it is suggested to set it at least twice bigger (height and width) than the masked object.
  • Page 34 H SIZE (00~80) Users can adjust the horizontal size of a privacy mask through this item. Set the H and V size to 0 can also delete the selected mask. V SIZE (00~60) Users can adjust the vertical size of a privacy mask through this item. Set the H and V size to 0 can also delete the selected mask.
  • Page 35: Time Setting

    3.3.22 Time Setting The time setting function is used to set the TIME related parameters of the Speed Dome Camera. Each item in the menu is listed as follows. TIME DISPLAY Select <ON> to display Time information on the screen or <OFF> not to display. YEAR / MONTH / DAY The items are for setting up the system date.
  • Page 36: Exit Osd

    PRESET Users can select the PRESET mode as an action carried out in a schedule point. SEQUENCE Users can select the SEQUENCE mode as an action carried out in a schedule point. AUTOPAN Users can select the AUTOPAN mode as an action carried out in a schedule point. CRUISE Users can select the CRUISE mode as an action carried out in a schedule point.
  • Page 37: Appendix A: Technical Specification

    Appendix A: Technical Specifications Item 12X PTZ Dome Camera CAMERA CCD Sensor 1/4" Super HAD II CCD Optical Zoom Digital Zoom 1× ~ 12× variable NTSC 380k/480k Effective Pixels 440k/570k Horizontal Resolution 650 TVL Scanning System NTSC / PAL Synchronization Internal / Line Lock Video Output 1.0 Vp-p / 75 Ω, BNC...
  • Page 38 Item 12X PTZ Dome Camera Alarm Input Alarm Output Alarm Reaction Preset, Sequence, Auto pan, Cruise GENERAL Environment Outdoor IP66 Controller Interface RS-485 Operating Temperature -22°F ~ 113°F (-30°C ~ 45°C) Dimension 11.1 x 7.6 in ( 131 x 200 mm) Weight 4.6 lbs (2.1 kg) Power Source...
  • Page 39: Appendix B: Switch Settings Index Table

    5. Appendix B: Switch Settings Index Table Refer to the switch setting menu below for the PTZ Dome Camera’s ID and Protocol setup. B.1 Camera ID Setup SWITCH SETTING ID No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 SW-9 SW-10 GVI Security...
  • Page 40 SWITCH SETTING ID No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 SW-9 SW-10 GVI Security...
  • Page 41 SWITCH SETTING ID No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 SW-9 SW-10 GVI Security...
  • Page 42 SWITCH SETTING ID No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 SW-9 SW-10 GVI Security...
  • Page 43 SWITCH SETTING ID No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 SW-9 SW-10 GVI Security...
  • Page 44 SWITCH SETTING ID No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 SW-9 SW-10 GVI Security...
  • Page 45 SWITCH SETTING ID No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 SW-9 SW-10 GVI Security...
  • Page 46 SWITCH SETTING ID No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 SW-9 SW-10 GVI Security...
  • Page 47: Protocol Setup

    SWITCH SETTING ID No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SW-7 SW-8 SW-9 SW-10 B.2 Protocol Setup SWITCH SETTING Protocol No. SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 GVI Security...
  • Page 48 GVI Security...
  • Page 49: Appendix C: Osd Menu Notes

    6. Appendix C: OSD Menu Notes Use the following OSD menu table to record various camera settings. PTZ Dome Camera Menu Tree Item Layer 1 Layer 2 Layer 3 Default AF MODE <NORMAL>, <Z. TRIG.>, <PTZ TRIG.> AUTO <AUTO> FOCUS EXIT + SAVE: YES <MANUAL>...
  • Page 50 Item Layer 1 Layer 2 Layer 3 Default PROPORTIONAL ZOOM <ON>, <OFF> AUTO CALI. <ON>, <OFF> PASSWORD <ON>, <OFF> OSD AUTO CLOSE <OFF>, <5> ~ <30> SEC. SYSTEM RESET <YES> SYSTEM RESET DEFAULT SYSTEM <YES> EXIT <YES> EXIT <YES> DEFAULT CAMERA <ON>, <OFF>...
  • Page 51 Item Layer 1 Layer 2 Layer 3 Default PRESET POINT <001> ~ <256> SEQUENCE LINE <001> ~ <008> AUTOPAN LINE <001> ~ <004> CRUISE LINE <001> ~ <008> <001> ~ <127> SEC., DWELL TIME ALWAYS <ALWAYS> EXIT DETECT SWITCH <ON>, <OFF> DETECT MODE <MOTION>...
  • Page 52 Item Layer 1 Layer 2 Layer 3 Default SET HOUR <00> ~ <23> SET MINUTE <00> ~ <59> EXIT+SAVE SCHEDULE <ON>, <OFF> SWITCH POINT <01> ~ <32> HOUR <00> ~ <23> MINUTE <00> ~ <59> NONE NO FUNCTION ☆ PRESET POINT PRESET <001>...
  • Page 53 GVI Security, Inc. Product specifications and manuals are also available at www.gviss.com. For additional assistance or information, please call GVI Security Technical Support using the following contact information. Telephone Number Email Address Location 888-595-2288 North America Technicalsupport@gviss.com Afterhours: 972-693-6402 Mexico 52-55-5682-9228 Technicalsupport@gviss.com Colombia...

Table of Contents