Carrier 58UVB series Installation, Start-Up, And Operating Instructions Manual page 45

Direct-vent upflow variable-capacity condensing gas furnace for sizes 060-120, series 100
Hide thumbs Also See for 58UVB series:
Table of Contents

Advertisement

TABLE 11 — ORIFICE SIZE* AND MANIFOLD PRESSURES FOR GAS INPUT RATE
(TABULATED DATA BASED ON 20,000 BTUH HIGH- -HEAT/13,000 BTUH LOW- -HEAT PER BURNER,
ALTITUDE
RANGE
HEAT VALUE
AT ALTITUDE
(ft)
7001
to
8000
8001
to
9000
9001
to
10000
* Orifice numbers shown in BOLD are factory-installed.
DERATED 2%/1,000 FT ABOVE SEA LEVEL) (CONT)
AVG. GAS
0.58
Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press
(Btu/cu ft)
No.
High/Low
650
43
3.8 / 1.6
675
43
3.5 / 1.5
700
44
3.8 / 1.6
725
44
3.5 / 1.5
750
44
3.3 / 1.4
775
45
3.7 / 1.6
800
45
3.5 / 1.5
825
45
3.3 / 1.4
625
43
3.8 / 1.6
650
43
3.5 / 1.5
675
44
3.7 / 1.6
700
44
3.5 / 1.5
725
44
3.2 / 1.4
750
45
3.7 / 1.5
775
45
3.4 / 1.5
600
43
3.8 / 1.6
625
43
3.5 / 1.5
650
44
3.7 / 1.6
675
44
3.4 / 1.4
700
44
3.2 / 1.3
725
45
3.6 / 1.5
A97386
SPECIFIC GRAVITY OF NATURAL GAS
0.60
0.62
No.
High/Low
No.
42
3.2 / 1.4
42
43
3.7 / 1.6
43
43
3.4 / 1.4
43
44
3.6 / 1.5
44
44
3.4 / 1.4
44
44
3.2 / 1.3
44
45
3.6 / 1.5
45
45
3.4 / 1.4
45
42
3.2 / 1.4
42
43
3.6 / 1.5
43
43
3.4 / 1.4
43
44
3.6 / 1.5
44
44
3.4 / 1.4
44
45
3.8 / 1.6
44
45
3.6 / 1.5
45
42
3.2 / 1.4
42
43
3.6 / 1.5
43
44
3.8 / 1.6
43
44
3.5 / 1.5
44
44
3.3 / 1.4
44
45
3.7 / 1.6
45
45
0.64
High/Low
No.
High/Low
3.4 / 1.4
42
3.5 / 1.5
3.8 / 1.6
42
3.2 / 1.4
3.5 / 1.5
43
3.6 / 1.5
3.8 / 1.6
43
3.4 / 1.4
3.5 / 1.5
44
3.6 / 1.5
3.3 / 1.4
44
3.4 / 1.4
3.7 / 1.6
44
3.2 / 1.4
3.5 / 1.5
45
3.6 / 1.5
3.3 / 1.4
42
3.4 / 1.5
3.8 / 1.6
42
3.2 / 1.3
3.5 / 1.5
43
3.6 / 1.5
3.7 / 1.6
44
3.8 / 1.6
3.5 / 1.5
44
3.6 / 1.5
3.2 / 1.4
44
3.3 / 1.4
3.7 / 1.6
45
3.8 / 1.6
3.3 / 1.4
42
3.4 / 1.4
3.7 / 1.6
43
3.8 / 1.6
3.4 / 1.5
43
3.6 / 1.5
3.7 / 1.5
44
3.8 / 1.6
3.4 / 1.4
44
3.5 / 1.5
3.8 / 1.6
44
3.3 / 1.4

Advertisement

Table of Contents