(9) Divide the final horizontal
angle reading by the number
of repetitions to calculate the
average angle value.
Example: If the final reading after 8 repetitions is 360°01'20",
To cancel or return to normal operation following repeat
horizontal angle measurement, depress the [HOLD] key again
until the third beep of the buzzer (approx. 1 sec.).
The maximum summed readout range is less than
±2000°/±2222.2222G.
If exceeded, the "OVER" warning will be displayed and
operation stops.
To reset, rotate the instrument in the reverse direction to display
the most recent repeat horizontal angle reading.
Repeat measurement cannot be performed when the MIL unit is selected.
36
the averaged reading will be:
360°01'20"/8 = 45°00'10"
VA:
114°27´40"
HA:
360°01´20"
VA:
114°27´40"
HA: OVER
RUN
RUN