Mean Time Between Failures - Quantum Tape Drive LTO-3 User Manual

Quantum lto-3 tape drive user's guide
Hide thumbs Also See for Tape Drive LTO-3:
Table of Contents

Advertisement

Chapter 5 Specifications

Mean Time Between Failures

Table 10 Reliability
Mean Time Between Failures
46
Specification
Non-recoverable error
rate
Error recovery and
control
Mean time between
failures (MTBF)
Cartridge load/
unload
Mean time to replace
(MTTR)
The mean time between failures (MTBF) for the internal drive is specified
at 250,000 hours minimum. This specification includes all power-on and
operational time but excludes maintenance periods. Operational time is
assumed to be 100% of the power-on time. Operational time is the time
the tape is loaded.
The MTBF for the desktop drive power supply is 50,000 hours with the
unit operated at full load and 25°C.
The MTBF rating does not represent any particular drive, but
Note:
is derived from a large database of test samples. Actual rates
may vary from unit to unit.
LTO-3 Tape Drive User's Guide
Description
17
Less than 1 in 10
bits
• Error correction code techniques
(C1 and C2 ECC)
• Read-after-write (RAW)
• Error monitoring and reporting (error log)
• Retry on
250,000 hours MTBF at 100% duty cycle:
power applied and tape moving continuously
(Desktop drive; 50,000 hours at full load and
25°C)
300,000 cartridge load/unload cycles (no
thread)
Less than 30 minutes
5

Advertisement

Table of Contents
loading

Table of Contents