PREPARING THE #TX-5v2
RCS TX-5v2
THESE INSTRUCTIONS REFER TO THE
2.4 GHz 5 CHANNEL R/C.
LAYOUT OF THE TX-5v2 TRANSMITTER HAND PIECE.
The valve gear knob is in the upper middle. The steam regulator knob sits just below.
Top left is the ON – OFF switch. Top right is the Bind/Ch # 5 pushbutton. (Can be used for uncoupling).
The other two knobs on end of the handpiece can be used for any servo controlled function.
These are AUX 1 = Ch # 2 & AUX 2 = Ch # 4. They are the best for
"playing"
a steam whistle.
1. "BINDING".
The 1st procedure is to "BIND" the receiver (RX) to the Transmitter (TX).
"BINDING" is accomplished by following a few simple steps below.
When binding we recommend removing the servos from the RX.
HOW TO "BIND" USING A DSM2 RX
MANUAL BINDING using a binding plug.
1.1 Insert the "BINDING" plug supplied with the DSM2 RX into the "BINDING" pins on the RX.
You can also use the # BINDER switch assembly if you do not wish to get inside the loco.
1.2. The RX LED will start blinking very rapidly to indicate it is ready to be bound.
AUTOMATIC BINDING = no binding plug.
1.3 Turn the Auto Bind RX ON and the RX LED will blink slowly looking for a TX. Wait 20 seconds for the RX to enter
bind mode. The RX LED (& slave front headlight if programmed to do so) will blink rapidly and is ready to be bound.
TURNING TX-5v2 ON
BINDING
CONTROLS & FUNCTIONS
1.4 Press
and hold
the right pushbutton on the handpiece marked with a hexagonal symbol.
You may need to keep
TX & RX about 1 x metre apart for binding to take place.
1.5 Then press
and hold
the ON – OFF button to ON. Hold both buttons until the RX LED stops flickering & starts
blinking slowly. Then let both TX buttons go. The TX button also blinks slowly & then goes to solid ON.
1.5 The LED on the RX will blink more slowly and then go solid ON.
1.5 The LED on the DELTANG ESC will behave the same.
1.6 When "BINDING" is complete the RX LED will change to solid ON.
N.B. "BINDING" plug
MUST
be removed
BEFORE
the SYSTEM is turned OFF.
1.7 The "BINDING" plug is removed & stored safely.