Figure 5-3 Charge Guard Wiring Diagram; Figure 5-4 Charge Guard Guide - Hughes 9450 Installation Manual

Mobile satellite terminal series
Hide thumbs Also See for 9450:
Table of Contents

Advertisement

IGN
+
Battery
Figure 5-3
Figure 5-4
Do not connect the Charge Guard in series with the positive
supply wire of the 9450 as this is a high current connection and
the impedance must be kept to a minimum.
+
Out
Charge
Guard
-
-
Use 14 AWG: up to 26ft (8m)
12 AWG: up to 40ft (12m)
10 AWG: up to 65ft (20m)
for the total length of the positive
and negative wires between the
battery and the 9450 in order to keep
the voltage drop to a minimum.
Charge Guard Wiring Diagram
Charge Guard Guide
IGN
9450 IDU
+
-
3004129-0001 Revision E