Feature
Measurement rate
Available units of
measurement
Storage temperature
Operating temperature
Battery type
Battery life
Dimensions
Directives, standards
and tests

9.2.7. testo 510i

Feature
Measuring range
Accuracy ± 1 digit
Overpressure
Resolution
Measurement rate
Available units of
measurement
Storage temperature
Operating temperature
Battery type
Battery life
Dimensions
Directives, standards
and tests
Values
1/sec
°C, °F, %RH, °Ctd, °Ftd, wetbulb °C, wetbulb °F
-20 °C to 60 °C / -4 to 140 °F
-20 °C to +50 °C / -4 to 122 °F
3 micro batteries AAA
150 h
243 mm × 30 mm × 24 mm
Probe shaft length 100 mm
EU guideline: 2014/30/EU
Values
-150 ... 150 hPa / 60 in wc
± 0.05 hPa (0 to 1.00 hPa) /
± 0.02 in wc (0 to 0.4 in wc)
± 0.2 hPa + 1.5% of m.v. (1.01 to 150 hPa)
± 0.08 in wc + 1.5% of m.v. (0.41 to 60 in wc)
500 mbar
0.01 hPa / 0.01 inch wc
2/sec
mbar, hPa, Pa, mmHg, inHg, in WC, psi, mmWC
In conjunction with Pitot tube (optional): m/s, fpm,
m³/h, cfm, l/s
-20 °C to 60 °C / -4 to 140 °F
-20 °C to +50 °C / -4 to 122 °F
3 micro batteries AAA
150 hrs
148 × 36 × 23 mm
EU guideline: 2014/30/EU