Siemens SINUMERIK 840DE User Manual page 57

Configuring the ncu sinumerik 840d series
Hide thumbs Also See for SINUMERIK 840DE:
Table of Contents

Advertisement

03.06
Operator controls
and displays
Table 4-11
Operator controls and displays
Designation
Type
RESET (S1)
Button
NMI (S2)
Button
S3
Rotary switch
S4
Rotary switch
H1 (left row)
LED
H2 (right row)
LED
H3
7-segment
1)
On the SIMATIC CPU 315-2DP, the LED is called "BUSF".
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition
Meaning
Triggering a hardware reset to reset the control and drive followed by a
complete restart.
Triggering an NMI request at the processor
NCK-startup switch
Position 0:
normal mode
Position 1:
startup position
Positions 2 to 7: reserved
PLC-mode switch
Position 0:
PLC–RUN
Position 1:
PLC–RUN–P
Position 2:
PLC–STOP
Position 3:
MRES
Illuminates if ...
+5V/POK: ... supply voltage is in tolerance range.
NF:
... NCK-Watchdog has activated and during the
startup phase.
CF:
... COM-Watchdog has activated.
CB:
... data transfer takes place via BTSS.
CP:
... data transfer takes place via PG MPI interface.
For NCUs with the MLFB ...-...-0AA0, the following applies:
NCU-internal voltage monitoring has switched off the power supply
(retentive) of the module if ...
POK
: Off
NF
: On
CF/CB/CP : undefined
H2
: undefined
Therefore, ensure that the recovery time after shutdown (re-activation via
power ON) is at least 10 s, because otherwise the voltage monitoring can
be activated.
Illuminates, ...
PR:
... if PLC-status = RUN
PS:
... if PLC-status = STOP
PF:
... + PR + PS + PFO: if PLC Watchdog has activated.
PFO:
... if PLC status = FORCE
1)
T/DP
: PLC-DP-status:
LED is off:
DP is not configured or
DP is configured, all slaves are found.
LED is flashing:
DP is configured, at least one slave is missing.
LED illuminates:
error (e.g. bus short-circuit, no token circulation)
Software-assisted output of test and diagnostics messages
4 Description of the NCU
4.3 NCU module interfaces
Fea-
ture
green
red
red
yellow
yellow
green
red
red
yellow
yellow
4-55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840dSinumerik 840d powerlineSimodrive 611 digital

Table of Contents