en | Configuration
ID
57=
58=
65=
66=
67=
68=
69=
71=
72=
Multiple SMS messages
Use multiple SMS messages for messages longer than 160 characters.
Double SMS example, part 1
ID
%1;
1=B450;
2=secret123;
15=3;
16=01020304050607080910
111213141516;
1
As you enter in the various ID's into your cell phone, do not
press the return key. Doing so will cause the B450 to ignore
the programming request.
Double SMS example, part 2
ID
%2;
19=1;
!
2
When you end the configuration programming with the
exclamation mark, do not enter any values. Doing so may
cause the B450 to ignore the programming request.
5.4.2

Sending the inbound SMS

1.
2.
3.
2017.10 | 09 | F.01U.300.740
Description
Session Keep Alive (0 to 1000 min)
Inactivity timeout (0 to 1000 min)
IPv4 DNS Server IP Address
Alternate IPv4 DNS Server IP Address
Panel programming
0 = disabled
1 = enabled
Reporting delay for low signal strength (0 - 3600 sec)
Reporting delay for no towers (0 - 3600 sec)
Modem reset count (0 - 99)
TCP keep alive time (0 - 255 sec)
Description
SMS sequence number
Tamper enabled
End of configuration
Make sure that the address switch on the B450 is set to 0.
Send the configuration SMS to the B44x module's phone number. The transmission might
take several minutes.
Observe the LEDs on the B450.
Installation and Operation Guide
Description
SMS sequence number 1
Current password
New password (case sensitive)
Enable AES encryption
Sample AES key
Conettix Plug-in Communicator Interfaces
1
Sample SMS
%1;1=B450;2=secret123;15=3;
16=010203040506070809101112131
41516;
2
Sample SMS
%2;19=1;!
Bosch Security Systems, Inc.