Setting Alarms

Navigation Alarms

Select Settings > Alarms > Navigation.
Arrival: Sets an alarm to sound when you are within a specified distance or
time from a turn or a destination.
Anchor Drag: Sets an alarm to sound when you exceed a specified drift
distance while anchored.
Off Course: Sets an alarm to sound when you are off course by a specified
distance.
Setting the Anchor Drag Alarm
You can set an alarm to sound if you have moved more than an allowable
distance. This is very useful when anchoring overnight.
1 Select Settings > Alarms > Navigation > Anchor Drag.
2 Select Alarm to turn on the alarm.
3 Select Set Radius, and select a distance on the chart.
4 Select BACK.

System Alarms

Clock: Sets an alarm clock.
Unit Voltage: Sets an alarm to sound when the battery reaches a specified
low voltage.
GPS Accuracy: Sets an alarm to sound when the GPS location accuracy
falls outside the user-defined value.

Collision Alarm

Before you can set a collision alarm, you must have a compatible AQUAMAP
connected to an AIS device or radar.
The safe-zone collision alarm is used only with AIS and MARPA. MARPA
AQUAMAP™ 10x2/12x2 SERIES
functionality works with radar. The safe zone is used for collision avoidance
and can be customized.
1 Select Settings > Alarms > Collision Alarm > On.
A message banner appears and an alarm sounds when a MARPA-tagged
object or an AIS-activated vessel enters the safe-zone area around your
boat. The object is also labeled as dangerous on the screen. When the
alarm is off, the message banner and audible alarm are disabled, but the
object is still labeled as dangerous on the screen.
2 Select Range and select a distance for the safe-zone radius around your
vessel.
3 Select Time To and select a time at which the alarm will sound if a target
is determined to intersect the safe zone.
For example, to be notified of a pending intersection 10 minutes before it
will likely occur, set Time To to 10, and the alarm will sound 10 minutes
before the vessel intersects the safe zone.

Sonar Alarms

NOTE: Not all options are available on all transducers.
From an applicable sonar view, select MENU > Sonar Setup > Alarms.
You can also open the sonar alarms by selecting Settings > Alarms >
Sonar.
Shallow Water: Sets an alarm to sound when the depth is less than the
specified value.
Deep Water: Sets an alarm to sound when the depth is greater than the
specified value.
FrontVü Alarm: Sets an alarm to sound when the depth in front of the
vessel is less than the specified value, which can help you avoid running
aground. This alarm is available only with Panoptix FrontVü transducers.
Water Temp.: Sets an alarm to sound when the transducer reports a
temperature that is 2°F (1.1°C) above or below the specified temperature.