Air Filter Element Replacement

1. Clean exterior of air filter housing.
2. Rotate end cover counterclockwise and remove
3. Remove air filter element by pulling it out of the
housing.
4. Clean interior of housing using a damp cloth. DO
NOT blow dirt out with compressed air.
5. At this time replace the element.
6. Reassemble in the reverse order of the disassembly.
SULL AIR
®
®
3000-4500 Operator's Manual and Parts List

6.8 SEPARATOR MAINTENANCE

Replace the separator element when indicated by the WS
Controller or after one (1) year, whichever comes first. The
separator element must be replaced. DO NOT attempt to
clean the separator element.

Separator Element Replacement

Refer to Figure 6-3. The separator element must be
changed when indicated by the WS Controller, or once a
year, whichever occurs first. Follow the procedure
explained below for separator element replacement:
NOTE
Relieve all pressure from the receiver
tank and all compressor lines.
1. Loosen and remove the eight (8) hex head capscrews
(M12 x 40mm) from the cover plate.
2. Lift the cover plate from the receiver tank.
3. Remove the separator element.
4. Inspect the receiver tank for rust, dirt, etc.
5. Reinsert the separator element into the receiver tank
taking care not to dent the element against the tank
opening.
6. Install a new lubricated O-ring in the O-ring groove on
the underside of the receiver tank cover.
7. Replace the cover plate, washers and capscrews.
Torque to 89 ft·lbs. (121 N·m).
8. Clean the return line strainer before restarting the
compressor.