Chapter 5 Trouble Shooting
No.
Failure
Machine cannot
1
power on
Laser power
2
supply cannot
power on
Alarm given
3
after power-on
Laser pause
4
during working
Wrong figure
5
size
Crash to the
machine and
6
unexpected
engraving
Analysis Method
Check whether the emergency
stop button pressed or not
The master contactor inside the
electrical box trip
The cooling system hasn't been
turned on normally
Water protection trigger (the
sensor broken)
The air switch of laser power
supply inside the electrical box trip
If parameters of the controller
are correct
Machine alarm signal is
triggered
Check if water circulation is
smooth
If power voltage is table
User adopts PLT output in
CoreIDraw
software.
dialogue box, if unit of plotter in
page option is set correct
User adopts PLT output in
CoreIDraw software. In HGPL
dialogue box, if zooming in page
option is 100%
If resolution of the controller
parameters are correct
Discharge and sparkle of the
laser tube (high voltage line ) to
case
Fail to connect earthing for the
controller or other interferences
Over high temperature causes
crash to the controller
- 53 -
Loosen the emergency stop
button
Reset master contactor
Open the water cycle system
Check the sensor of water
protection
Close the air switch of laser
power supply
Correct parameters of
the controller
Check alarm signal
source of the machine
Clean water tank, dredge
water hose
Install a stabilizer to input
power supply
PLT plotter unit out from
CoreIDraw software should
In
HGPL
match with resolution of
SmartCarve software lead-in
PLT option
Change to 100%
Set to the correct resolution
or equivalent
Reconnect the laser tube
high voltage line
Connect earthing, eliminate
the interference
Add more measures for
lowering temperature
Solution