Mode And Display Operation - Sentry Voyager 12V 60A Installation & Operation Manual

Marine battery chargers
Table of Contents

Advertisement

Mode and display operation

MODE
INITIALIZATION
BOOST
PHASE
ABSORPTION/
EQUALIZATION
PHASE
FLOATING
PHASE
MAIN
VOLTAGE
FAULT
CHARGER
TEMPERATURE
FAULT (TEMP)
DESCRIPTION
Charger powered
on and/or Chan-
ge of charging
cycle
Batteries in
charging phase
(charge from 0 to
80%)
Batteries in
charging phase
(charge from 80%
to 100%)
End of the equali-
zation cycle within POWER ON
a period of 30
minutes
Charging cycle
completed
(charge at 100%)
Main voltage
fault, excessively
high or abnormally
Low voltage
Immediate auto-
matic restart,
subject to
disappearance of
the fault
Excessive charger
temperature fault
Automatic restart
after a
min delay
for 30 seconds,
subject to
disappearance of
the fault
FLASHING
SOLID LED
LED
All LEDs
for 3
seconds
POWER ON
BOOST
POWER ON
ABS
POWER ON
FLOAT
POWER
-
ON
TEMP
18
-
-
-
ABS
-
-

Advertisement

Table of Contents
loading

Table of Contents