Sentry Voyager 12V 60A Installation & Operation Manual page 22

Marine battery chargers
Table of Contents

Advertisement

HS
temperature
sensor
General
main supply
fault
General
battery supply
fault
Circuit Board
Operating
temperature
Storage
temperature
Humidity
Convection
Housing
Protection
rating
Mounting
Overall dimen-
sions (Depth x
Width x Height)
Weight
EMC
SAFETY
Display
Main
connector
Battery
connectors
Battery sensor
connector
Alarm relay
connector
External
CAN bus
connectors
12V 60A - 12V 90A
24V 40A - 24V 60A
"Shutdown" type with automatic restart
once the fault has disappeared
Main fuse
Output fuses on –DC supply
Conformal Coated protection on
circuit board
14°F to +130°F
(-10°C to +55°C)
-4°F to +158°F
(-20°C to +70°C)
10% to 90% (without condensation)
Forced by thermostat-controlled fan
Wall-mounted housing in painted
aluminium
Using 4 x #8 (4mm Ø) screws
125 x 340 x 360 mm
4.9 x 13.4 x 14.2 inches
13.2lbs (6 Kg)
EN55014-1
EN60335-2-29
Front LED display
3-point cage terminal for cables with a
cross-section of 6AWG10mm2 max
M8 pins
2-point cage terminal for cables with a
cross-section of 16AWG1.5mm2 max
2-point cage terminal for cables with a
cross-section of 16AWG1.5mm2 max
2 x RJ11 connectors (CAN bus)
24V 100A
IP20
190x340x 360
7.5x13.4x 14.2
25.4lbs (11.5
kg)
22