6.3 Indicator lamp in the charging station

For a fully functional installation, the indicator lamp in the charging station must emit a solid green light. If something
else appears, follow the troubleshooting guide below.
If you still need help with troubleshooting, please contact your local McCULLOCH representative.
Light
Cause
Solid green light
Everything in order
Green flashing light
The signals are good and
vated.
Blue flashing light
The boundary loop is not connected to the
charging station
Break in the boundary loop
Yellow flashing light
The guide wire is not connected to the charg-
ing station
Break in the guide wire
Red flashing light
Interruption in the charging station's antenna
Solid red light
Fault in the circuit board or incorrect power
supply in the charging station. The fault
should be rectified by an authorized service
technician.
42 - Troubleshooting
Action
No action required
ECO mode is acti-
No action required. For more information on
ECO mode , see ECO mode on page 26 .
Check that the boundary wire connector is fit-
ted properly to the charging station. See
necting the boundary wire on page 18 .
Find out where the break is. Replace the
damaged section of the boundary wire with a
new loop wire and splice using an original
coupler. See
page 44 .
Check that the guide wire connector is prop-
erly connected to the charging station. See
Laying and connecting the guide wire on
page 19
Find out where the break is. Replace the
damaged section of the guide wire with a new
loop wire and splice using an original coupler.
Contact your local McCULLOCH representa-
tive.
Contact your local McCULLOCH representa-
tive.
Con-
Find breaks in the loop wire on
358 - 002 -