A bleed-type master air valve (B) is required to shut
off an relieve air pressure that may be trapped in the
air motor. Trapped air could cause the pump to cycle
unexpectedly and cause serious bodily injury,
including amputation.
A
B
F
. 2: Typical Installation
IG
Key:
A
Grounded air line
B
Bleed-type master air valve
C
Air filter
D
Air line oiler
E
Air regulator
F
Grounded dispensing hose
G
Dispensing valve
H
Elevator assembly with inductors
J
Ground wire
306674W
C
D
E
H
Be sure the air hose is properly sized to deliver an ade-
quate supply of air to the motor. Refer to the Technical
Data on page 16.
Connect a dispensing hose to the 3/8 npt(f) pump outlet.
Install an appropriate gun or dispense valve to the hose.
Ground the pump as explained on page 4.
J