7.5. AUX Output Connection
Use the supplied removable terminal plugs (6 pins) for connection.
AUX output is set to LINE level input.
For removable terminal plug connections, see p. 12.
From mixer or
amplifier
[AUX output]
Removable terminal block (6 pins)
+4 dB*, 10 kΩ,
balanced (electronically-balanced)
7.6. Control Input and Output Connections
Use the supplied removable terminal plug (6 pins) for connection.
Connect the control input and output blocks using 2 control lines from external control devices.
For removable terminal plug connections, see p. 12.
For contact input and output functions, see p. 16.
L line
R line
* 0 dB = 0.775 V
[Control outputs 1-2]
Removable terminal block (6 pins)
Relay contact output
Withstand voltage: 40 V DC
Control current: 2 to 300 mA
From control input
terminals of external
control devices
C
2
1
C
2
1
[Using a 2-core shielded wire]
From mixer or
amplifier
[Using a single-core shielded wire]
From mixer or
amplifier
[Control inputs 1-2]
Removable terminal block (6 pins)
No-voltage make contact input
Open-circuit voltage: 12 V DC or less
Short-circuit current: 2 mA or less
From control output
terminals of external
control devices
H
C
E
H
C
E
11