Electrical; Physical; Certification; Applicable Standards - Honeywell Sensepoint Technical Manual

Gas detector
Hide thumbs Also See for Sensepoint:
Table of Contents

Advertisement

Electrical

Flammable
3-wire mV bridge
2.9-3.5 Vdc, 0.7 W (max.),
constant current operation at
200 mA

Physical

Flammable Sensor
Polyphenylene Sulfide
Material
(PPS)
190 g
Weight

Certification

Flammable
Ex II 2 G D EEx d IIC
T6 T85°C
T
= -55°C to +55°C
amb
BAS98ATEX2156X
SIRA03ATEX1116X
- Performance
Also see page 33.

Applicable Standards

Flammable
Standard
EN50270

Environmental

IP rating
Operating temperature
Operating humidity range
Operating pressure
Storage conditions
2106M0525 Iss 2 Nov 05
Toxic/Oxygen
2-wire loop powered
4-20 mA (plus screen),
16-30 Vdc, 0.9 W
Toxic/Oxygen Sensor
Polyphenylene Sulfide
(PPS)
185 g
205 g oxygen
Toxic/Oxygen
Ex II 2 G D EEx d ia IIC
T4 T135°C
T
= -55°C to +65°C
amb
BAS90ATEX2157X
Toxic
EN445544 (H
IP65, IP66 with Weather housing in accordance with
EN60529:1992
Dependent upon gas type and certification
Continuous: 20-90% RH (non-condensing)
Intermittent: 10-99% RH (non-condensing)
90-110 kPa
Instrument -40°C to +50°C (-40°F to +122°F).
Enclosure
Earth continuity plate
BK4 4-wire Terminal block
4-wire, 0.5 to 2.5 mm
AWG). Cable entries: 1 x M20,
1 x ½ in. NPT, 1 x ¾ in. NPT
Enclosure
Fire retardant Glass Filled
Polyester (GFP)
600 g
Enclosure
Ex II 2 G D EEx e II
T6 T85°C
T
= -40°C to +50°C
amb
SIRA04ATEX3018
EMC
S only)
EN50270
2
Specifications
2
(20 -14
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents