Notes on safety for the installation

After carefully cleaning all around the area where the burner will
be installed, and arranging the correct lighting of the environ-
ment, proceed with the installation operations.
All the installation, maintenance and disassembly
operations must be carried out with the electricity
supply disconnected.
DANGER
4.3

Handling

The packaging of the burner includes a wooden platform, so it is
possible to move the burner (still packaged) with a transpallet
truck or fork lift truck.
With regard to the transport in the obligatory passages, refer to
the burner dimensions shown in Fig. 3, page 8.
The handling operations for the burner can be high-
ly dangerous if not carried out with the greatest at-
tention: keep any unauthorised people at a
WARNING
distance; check the integrity and suitableness of the
available means of handling.
4.4

Preliminary checks

Checking the consignment
After removing all the packaging, check the integrity
of the contents. In the event of doubt, do not use the
burner; contact the supplier.
CAUTION
The packaging elements (wooden cage or card-
board box, nails, clips, plastic bags, etc.) must not
be abandoned as they are potential sources of dan-
ger and pollution; they should be collected and dis-
posed of in the appropriate places.
4.5

Working position

The burner must be installed in conformity with leg-
islation and local standards.
WARNING
The burner is designed to work only in the positions 1, 2, 3 and 4
(Fig. 5).
Any other position could compromise the correct
working of the appliance.
Installation 4 is not recommended for safety rea-
DANGER
sons.
Installation 5 is forbidden for safety reasons.
Installation
The installation of the burner must be carried out by
qualified personnel, as indicated in this manual and
in accordance with the regulations of authorities
WARNING
having jurisdiction.
Reference for the recommended installation prac-
tises shall be made to NFPA#31 for USA, CSA
Standard B139 (oil burner only) for Canada.
Oil-burning equipment shall be connected to flues
having sufficient draft at all times, to assure safe
and proper operation of the burner.
Check also that the area in which you are working is empty and that
there is an adequate escape area (i.e. a free, safe area to which
you can quickly move if the burner should fall). During the handling,
keep the load at not more than 10" from the ground.
After positioning the burner near the installation
point, correctly dispose of all residual packaging,
separating the various types of material.
CAUTION
Before proceeding with the installation operations,
carefully clean all around the area where the burner
will be installed.
The output of the burner must be within the boiler's
firing rate.
WARNING
A burner label that has been tampered with, re-
moved or is missing, along with anything else that
prevents the definite identification of the burner
WARNING
makes any installation or maintenance work diffi-
cult.
1
4
11
2
3
S8218
5
20045701
Fig. 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rdb2.2r t1 bf fcx2220045453Rdb2.2r t3 bf fcx30

Table of Contents