3
Technical description of the burner
3.1
Technical data
Model
Output
(1)
Delivery
(1)
Fuel
Operation
Nozzle
Ambient temperature
Combustion air temperature
Main power supply (+/- 10%)
Electric motors
Motor
Ignition transformer
Delivery (at 174 PSI)
Pump
Pressure range
Electrical power consumption
Reference conditions: ambient temperature 68 °F (20°C) - Barometric pressure 394" WC - Altitude 329 ft.
(1)
Equivalent Btu values based on 1 USGPH = 140,000 Btu/hr.
(2)
BF (Direct Vent Application) or CF (Chimney Vent Apllication)
*
# 1 ASTM D 396 & # 2 Fuel Oil
3.2
Burner models designation
Model
RDB 2.2R T1 BF FCX22
RDB 2.2R T3 BF FCX30
3.3
Accessories (optional)
•
CF conventional flue conversion kit
•
Light oil filter
NOTE:
The installer is responsible for the supply and installation of
any required safety device(s) not indicated in this manual.
20045701
Technical description of the burner
RDB 2.2R T1 BF FCX22
Btu/hr
(2)
GPH
number
°F
°F max
V/Ph/Hz
rpm
V
W - HP
A
µF
GPH
PSI
W max
Code
Voltage
20045452
120/1/60
20045453
120/1/60
6
70.000 - 98.000
0.50 - 0.70
# 1 and # 2 Fuel Oil
Single stage
1
32 - 104
140
Single phase, ~ 60Hz 120V ± 10%
3450
120
90 - 0.12
2.2
12.5
Secondary 8 kV - 16 mA
15
116 - 217
150 - 0.2
Flame safeguard
Burner mounted
Burner mounted
RDB 2.2R T3 BF FCX30
81.200 - 154.000
0.58 - 1.10
Tab. A