Installation; Installation Precautions - Riello 20045452 Installation, Use And Maintenance Instructions

Light oil burners
Table of Contents

Advertisement

4

Installation

4.1

Installation precautions

AIR FOR COMBUSTION
Do not install burner in room with insufficient air for combustion. Be sure there is an adequate air supply for combustion if
the boiler room is enclosed. It may be necessary to create a window to permit sufficient air to enter the boiler room.
WARNING
The installer must follow local ordinances in this regard.
CANADA It is suggested that the installer follow CSA standard B139.
USA
It is suggested that the installer follow NFPA manual #31.
CHIMNEY
Be sure chimney is sufficient to handle the exhaust gases. It is recommended that only the burner be connected to the
chimney. Be sure that it is clean and clear of obstructions.
OIL FILTER
An external oil filter is REQUIRED, even though there is an internal strainer in the pump.
The filter should be replaced at least once a year, and the filter container should be thoroughly cleaned prior to installing
a new filter cartridge.
DRAFT
Follow the instructions furnished with the heating appliance.
The pressure in the combustion area should be kept as close to zero as possible. The burner will operate with a slight draft
or pressure in the chamber.
ELECTRICAL CONNECTIONS
CANADA All electrical connections should be done in accordance with the C.E.C. Part 1, and all local codes.
The system should be grounded.
USA
All electrical connections should be done in accordance with the National Electrical Code, and all local ordi-
nances. The system should be grounded.
CONTROL BURNER OPERATION
Check out the burner and explain its operation to the homeowner. Be sure to leave the Owner's Instruction sheet with the
homeowner.
FIRE EXTINGUISHER
If required by local codes, install an approved fire extinguisher.
ELECTRICAL CONNECTIONS
In most localities, a number 14 wire should be used inside a metal conduit. The system should be grounded.
A service switch should be placed close to the burner on a fireproof wall in an easily accessible location.
The burner settings used in this manual were obtained under laboratory conditions and may vary from those ob-
tained in the actual installation of the burner.
Combustion results must be verified using proper combustion test equipment.
Riello will not be responsible for the improper installation or set-up of the appliance.
WARNING
20045701
Installation
10