Key Automation VIPER LED VIP7U Installation And Use Instructions Manual page 25

Opener for sectional and up and over garage door
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
4.9 Setting of closing limit
Press"+" to display "2"
When the door closes and
reaches the ideal position, after
2 seconds press the key "P" to
save the information.
4.10 Force learning activation
Press"+" to display "3"
Door closes automatically
4.11 Setting force level
Note: in order to exit the programming and save the parameters push P button for 5 seconds.
Press"+" to display "4"
High
When programming is finished the door must make a full cycle before usage, this cycle is used to learn the force after the modification made.
Press "P", "2" will flash
Press "P", "3" flashes
Press "P" to save the settings
Press "P", " " flashes
Default setting
Force level
Press"+"
Or press "-"
Attention!! In order to avoid false obstacles detection in closing while
programming the motor it is strongly recommended to release the but-
ton as soon as the door touch the ground.
The door opens automatically
Press"+", or press"-" to select
the level
Door closing
Or door opening
Press "P" when door stops,
then again press "P"
Press "P" to save the settings
Low
EN
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents