Key Automation VIPER LED VIP7U Installation And Use Instructions Manual page 27

Opener for sectional and up and over garage door
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
4.16 Opening command setting
It is possible to change the functioning of the open/stop/close command to only open
Press"+" to display "9"
Note: in order to exit the programming and save the parameters push P button for 5 seconds.
4.17 Override and disabling of photocell detection
1) It is possible to override closure of the sectional door, even when the photocell contact is open.
- With the door open, press the transmitter button or DOOR command; the automation then signals failure of the closed photocell contact
by emitting three consecutive beeps.
- Release the transmitter button or DOOR command, and within 4 seconds press and hold the same command;
the automation will then override closure for as log as the command (HOLD-TO-RUN) is pressed.
2) It is possible to select a point of photocell detection exclusion from the ground, by means of function "A" (last item after function "9")
A
After parameter "9" press
"+" to display "A"
Value
0
1
Photocell detection disabled at 10 cm from point of closure
2
Photocell detection disabled at 20 cm from point of closure
3
Photocell detection disabled at 30 cm from point of closure
4
Photocell detection disabled at 40 cm from point of closure
5
Photocell detection disabled at 50 cm from point of closure
6
Photocell detection disabled at 60 cm from point of closure
7
Photocell detection disabled at 70 cm from point of closure
8
Photocell detection disabled at 80 cm from point of closure
9
Photocell detection disabled at 90 cm from point of closure
Note: in order to exit the programming and save the parameters push P button for 5 seconds.
Press "P", the display shows
"0" to indicate that the step/step
command has the Open/Stop/
Close function (default setting)
Press "P"; the display shows
"0" to indicate that the function
is
disabled,
and
therefore
photocell detection is active
throughout the stroke (factory
setting)
Description
Photocell detection enabled
Press"+", "1" appears to indi-
cate that the step/step com-
mand can only open
Press "+" to select the detection
exclusion height of the required
photocell (see table below)
By enabling this function, the
Step/Step command permits
opening by accepting only re-
opening during closing.
With the function "7=1" auto-
matic closure enabled at each
command the automatic closing
time is updated
With the function "7=0" automat-
ic closure disabled with the door
open it is possible to reclose it
using the step/step command
EN
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents