Atlas Copco GA 15 Instruction Book page 81

Oil-injected rotary screw compressors
Hide thumbs Also See for GA 15:
Table of Contents

Advertisement

Instruction book
Menu icon, Outputs
Function
To call up information regarding the actual status of some outputs such as the condition of the Fan overload
contact (on air cooled compressors), the Emergency stop contact, etc.
Procedure
Starting from the Main screen (see
• Move the cursor to the action button Menu and press the Enter key. Following screen appears:
Text on figure
(1)
(2)
• Move the cursor to the Outputs icon (see above, section Menu icon, using the Scroll keys.
• Press the Enter key. A screen similar to the one below appears:
(1)
(2)
(3)
(4)
(5)
• The screen shows a list of all outputs with their corresponding icons and readings.
• If an input is in warning or shutdown, the original icon is replaced by the warning or shutdown icon
respectively.
2920 7083 31
Main
screen),
Menu
Regulation
Outputs
Fan motor contact
Blow-off contact
General shutdown
Automatic operation