Atlas Copco GA 15 Instruction Book page 149

Oil-injected rotary screw compressors
Hide thumbs Also See for GA 15:
Table of Contents

Advertisement

Instruction book
UL/cUL versions
For UL designed industrial control panels, calculations for cable sections and fuses are done according to
UL508a (Industrial control panels).
For cUL, calculations for cable sections and fuses are done according to CSA22.2 (Canadian electrical code).
Standard conditions: maximum 3 copper conductors in raceway or cable with 85-90˚C (185-194 ˚F)
insulation at ambient temperature 30 ˚C (86 ˚F), operating at nominal voltage; cables not grouped with other
cables.
Worst case conditions: ambient temperature > 30 ˚C (86 ˚F), max. 3 copper conductors in raceway or cable
with 85-90 ˚C (185-194 ˚F) insulation at 46 ˚C (115 ˚F) ambient temperature and operating at nominal voltage.
Cables not grouped with other cables.
Fuse size is the maximum fuse size in order to protect the motor against short circuit. For cUL fuse HRC form
II, for UL fuse class RK5.
If the local conditions are more severe then the described standard conditions, the cables and fuses for worst
case conditions should be used.
Recommended cable size
Type
V
GA 15
230
GA 15
400
GA 15
500
GA 15
380
GA 15
200
GA 15
230
GA 15
460
GA 15
575
GA 18
230
GA 18
400
GA 18
500
GA 18
380
GA 18
200
GA 18
230
GA 18
460
GA 18
575
GA 22
230
GA 22
400
GA 22
500
GA 22
380
GA 22
200
GA 22
230
GA 22
460
2920 7083 31
Hz
Approval
I
P
tot
(1)
50
IEC
62
50
IEC
36
50
IEC
29
60
IEC
36
60
UL/cUL
67
60
UL/cUL
58
60
UL/cUL
29
60
UL/cUL
23
50
IEC
74
50
IEC
43
50
IEC
34
60
IEC
44
60
UL/cUL
84
60
UL/cUL
72
60
UL/cUL
36
60
UL/cUL
29
50
IEC
91
50
IEC
54
50
IEC
43
60
IEC
56
60
UL/cUL
103
60
UL/cUL
94
60
UL/cUL
47
I
FF
Recommended wire
tot
section (2)
(1)
67
2
4 x 25 mm
41
2
4 x 10 mm
34
2
4 x 10 mm
41
2
4 x 10 mm
72
4 x AWG2
64
4 x AWG3
34
4 x AWG6
29
4 x AWG8
79
2
4 x 35 mm
48
2
4 x 16 mm
39
2
4 x 10 mm
49
2
4 x 16 mm
89
4 x AWG2
77
4 x AWG3
41
4 x AWG6
34
4 x AWG6
97
2
4 x 50 mm
59
2
4 x 25 mm
48
2
4 x 16 mm
61
2
4 x 25 mm
108
4 x AWG1/0
99
4 x AWG1
52
4 x AWG4
Recommended wire
Main
section (3)
fuses
(A) (4)
2
80
4 x 35 mm
2
50
4 x 16 mm
2
50
4 x 16 mm
2
50
4 x 16mm
4 x AWG2
100
4 x AWG2
80
4 x AWG6
50
4 x AWG6
40
100
2
4 x 50 mm
63
2
4 x 25 mm
50
2
4 x 16 mm
63
2
4 x 25 mm
4 x AWG1
125
4 x AWG2
100
4 x AWG4
50
4 x AWG6
50
2
125
4 x 70 mm
80
2
4 x 35 mm
63
2
4 x 25 mm
80
2
4 x 35 mm
4 x AWG1/0
125
4 x AWG1/0
125
4 x AWG3
80
147