Atlas Copco GA 15 Instruction Book page 145

Oil-injected rotary screw compressors
Hide thumbs Also See for GA 15:
Table of Contents

Advertisement

Instruction book
Condition
Excessive oil consumption; oil
carry-over through discharge line
Safety valve blows after loading
Compressor element outlet
temperature or delivery air
temperature above normal
Faults and remedies, dryer
For all references hereafter, consult section
Condition
Pressure dew point too high
2920 7083 31
Fault
Solenoid valve malfunctioning
Leak in control air tubes
Inlet valve does not fully open
Oil separator clogged
Air leakage
Safety valve leaking
Compressor element out of order
Incorrect oil causing foam
Oil separator defective
Malfunctioning of the scavenge line
Inlet valve malfunctioning
Minimum pressure valve
malfunctioning
Safety valve out of order
Compressor element out of order
Oil separator element clogged
Oil level too low
On air-cooled compressors,
insufficient cooling air or cooling air
temperature too high
Oil cooler clogged
Bypass valve malfunctioning
Air cooler clogged
Compressor element out of order
Air
dryer.
Fault
Air inlet temperature too high
Ambient temperature too high Check and correct; if necessary, draw
Shortage of refrigerant
Refrigerant compressor does
not run
Remedy
Replace valve
Replace leaking tubes
Have valve checked
Replace oil separator element
Have leaks repaired
Have valve replaced
Consult Atlas Copco
Change to correct oil
Replace oil separator element
Replace non-return valve in the
scavenge line
Have valve checked
Have valve checked
Have valve replaced
Consult Atlas Copco
Replace oil separator element
Check and correct
Check for cooling air restriction or
improve ventilation of the
compressor room. Avoid
recirculation of cooling air. If
installed, check capacity of
compressor room fan
Clean cooler
Have valve tested
Clean cooler
Consult Atlas Copco Customer
Centre
Remedy
Check and correct; if necessary, clean the
aftercooler of the compressor
cooling air via a duct from a cooler place or
relocate the compressor
Have circuit checked for leaks and recharged
See below
143

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga 18Ga 22

Table of Contents