Instruction book
and wait a few minutes. Remove the plug and top up oil, until the sight-glass is full. Fit and tighten the plug
(FC).
On compressors with an Elektronikon® controller, unlock the emergency stop button (10) and press the 'Rset'
key (5) before restarting.
On compressors with an Elektronikon® Graphic controller, unlock the emergency stop button (10), select the
STOP icon on the display and press reset before restarting.
Air filter
Especially if the compressor is installed in a dusty environment, inspect the air filter element regularly. Replace
when necessary. See also
Drains
Regularly check that condensate is discharged during operation. See section
of condensate depends on environmental and working conditions.
2920 7083 31
Position of oil level sight-glass on GA 15 up to GA 22
Preventive maintenance schedule
for periodic replacement instructions.
Condensate
system. The amount
127