Ground Connection; Mounting Brackets; Rf Ports; Figure 4: System - Rdl-2000 Rf Ports - Redline RDL-2000 User Manual

Advanced broadband wireless infrastructure solutions
Table of Contents

Advertisement

Customer equipment including personal computers, routers, etc., must be connected
only to the INPUT (DATA) port on the PoE unit.
Only the outdoors Ethernet interface cable connecting to the RDL-2000 can be safely
connected to the OUTPUT (DATA & POWER) connector. Connecting customer
premises Ethernet equipment directly to the OUTPUT (DATA & POWER) connector
on the PoE power adapter may damage customer equipment.
\\
2.3

Ground Connection

A ground-lug is provided on the RDL-2000 chassis for connection to the local grounding
system.
2.4

Mounting Brackets

The heavy-duty (four-point) mounting bracket can be used to mount the RDL-2000 and a
flat panel antenna. The RDL-2000 can also be mounted using just the mounting adapter
plate and the supplied hose clamps when used with parabolic antennas or other antenna
not compatible with the heavy duty mounting bracket. Refer to the RDL-2000 Installation
Guidelines manual for a detailed description of mounting options.
2.5

RF Ports

The RF ports (2x female TNC connectors) conduct RF signals between the RDL-2000
and external antenna system. RF Port 0 is always enabled and should be used if
operating in SISO mode (single antenna). RF Port 1 is enabled by checking the MIMO
selection during system configuration. A pair of N-to-TNC coaxial jumper cables are
provided to connect the RDL-2000 antenna system.
70-00143-01-01a
RDL-2000
Warning to Service Personnel: 48 VDC

Figure 4: System - RDL-2000 RF Ports

Proprietary Redline Communications © 2010
User Manual
Page 13 of 50 September 24, 2010

Advertisement

Table of Contents
loading

Table of Contents