2000 units. Power from a PoE connected to either unit is conducted over the
interconnecting cable.
Refer also to the Enable Security (VLAN) field in section 3.5: Advanced Screen on
4.
page 24.
2.2

Indoor PoE Power Adapter

The RDL-2000 is powered using a PoE power adaptor. The Redline supplied PoE power
adaptor source is auto-sensing 110-240 VAC (nominal). The RDL-2000 is shipped with a
power cord compatible with the North American power system.
<
The Ethernet outdoor cable is supplying a protective ground connection for the Ethernet
cable. Customer supplied PoE devices must have metal-lined RJ-45 sockets providing a
protective ground connection to the cable shield.
Use a straight-through cable when connecting to a PC or router, or a cross-over cable to
connect the PoE "Data" port directly to a switch.
Note: The RDL-2000 Ethernet port uses a custom pinout for the PoE signals. All
Ethernet cables from the indoor PoE to the outdoor RDL-2000 must be terminated to
match Table 2: System - Ethernet Port Wiring on page 11.
Port
INPUT
DATA
OUTPUT
DATA & POWER
70-00143-01-01a
RDL-2000
Important -- PoE Equipment

Figure 3: System - PoE Power Adaptor

Table 3: System - PoE Ports

Description
10/100Base-T Ethernet port (RJ-45 socket) for connection to the local
network equipment.
10/100Base-T Ethernet port (RJ-45 socket) and 48 VDC power for
connection to the RDL-2000.
Proprietary Redline Communications © 2010