5.2 SETUP MENU parameter details

a. To enter the SETUP Menu, press and hold the SETUP-button during 3 seconds.
The "Menu" icon will light up.
b. Press the "-" or "+" button to scroll.
Table 3 below lists in order off appearance all parameters which can be adjusted when pressing
the "-" button
c. Press SELECT: the parameter to change will now blink.
d. Use the "-" or "+" button to chose the desired value.
e. Press SETUP to confirm the change, the value will stop blinking, and the change is made final.
With the "-" or "+" button it is now possible to scroll to another parameter that needs change.
f. To return to normal mode, press SETUP during 2 seconds.
Function or
Visible icons
parameter
On-off switch
Menu + Charging
System reset to
Menu
default settings
Temperature
menu + thermometer
0
0
C or
F
Absorption time
Menu + Battery + Abs
Bulktime
Menu + Battery +
protection
Bulk
Battery
Menu + Battery +
temperature
thermometer
compensation
Low battery
Menu + Battery
voltage alarm
High battery
Menu + Battery
voltage alarm
Manual
Menu + Battery +
Equalisation
Equalise
Automatic
Menu + Battery +
Equalisation
Equalise
Equalisation
Menu + Battery +
voltage
Equalise
Float voltage
Menu + Battery +
Float
Absorbtion
Menu + Battery+ Abs
voltage
Charge
Menu + Battery
algorithm
System voltage
Menu + Battery
Relay function
Menu
KWh-meter
Menu + Battery
reset
Maximum
Menu + Battery +
charge current
Bulk
(bulk-current)
Table 5: Setup menu parameter details
Text or value
units
visible on
alphanumerical
display
ON or OFF
rESEt
0
0
0
C or
F
C /
Value
h
OFF or value
h
Value
mV/
per cell
Lb+value
V
Hb + value
V
StArt
(blinking)
OFF or AUto
Value
V
Value
V
Value
V
Number or USr
type
Value or AUto
V
rEL. + number
Value
kWh
Value
A
Range and
default (bold)
ON - OFF
0
0
F
0
C /
F
1 - 24
Default:see table 3
OFF – 10h
0
C
-3,5 - 2,7 - 0 - 3,5
32,0 - 40,0 - 69,6
32,0 - 60,0 - 69,6
StArt
(blinking or solid)
OFF - AUto
32,0 - 64,8 - 69,6
32,0 - 55,2 - 69,6
32,0 - 57,6 - 69,6
1,2,3,4,5, 6, 7,
USr
12, 24, 36, 48,
AUto
1, 2, 3, 4 5, 6, 7
OFF
0 – 999.999
1,0 – 70,0
Step size
(1)
1 h
0,1mV (2)
0,1V
0,1V
(3)
0,1V (2)
0,1V (2)
0,1V (2)
(4)
1,0
9