1-12. Installation Instructions

Outdoor Unit
1.
Tubing Length
(A) Single type
During tubing work, try to make both the tubing length (L)
and the difference in elevation (H1) as short as possible.
Refer to Table 1-1.
Table 1-1 Tubing Data for Models (Single)
Tubing Data
Tubing size outer
diameter
Limit of tubing length (L)
Height Differential
of Indoor / Outdoor
Units (H1)
Max. allowable tubing length at
s
h
p i
m
e
t n
Required additional refrigerant
Refrigerant charged at shipment
No additional charge of compressor oil is necessary.
* If the total tubing length exceeds 30 m, charge the amount of refrigerant as
shown above in "Required additional refrigerant" for every 1 m in excess of
30 m for outdoor units.
AMP Air Conditioning
Models
U-200PE2E8A
Liquid tube
mm (in.)
Gas tube
mm (in.)
(m)
Outdoor unit is
placed higher
(m)
Outdoor unit is
placed lower
(m)
(
m
)
(
/ g
m
)
k (
) g
U-250PE2E8A
9.52 (3/8)
12.7 (1/2)
25.4 (1)
120
30
30
5 - 30
50*
5.60
1-34
Single
Main tubing L
80*
6.40
www.ampair.co.uk | sales@ampair.co.uk