Wyrestorm MX-0404-H2 v2 Quick Start Manual

Wyrestorm MX-0404-H2 v2 Quick Start Manual

4x4 or 6x6 4k hdmi matrix switcher with hdcp 2.2 encryption
Hide thumbs Also See for MX-0404-H2 v2:

Advertisement

4x4 or 6x6 4K HDMI Matrix Switcher
with HDCP 2.2 Encryption
MX-0404-H2 v2 | MX-0606-H2 v2
Note:
IMPORTANT! Installation Requirements
Recommended Products
Basic Wiring Diagram
AC Mains
LAN
HDMI
UHD Source
RS-232 to Control System
HDMI
UHD Source
In the Box
Additional Information
HDMI
HDMI
UHD Display
Quickstart Guide
KEY
HDMI
HDBaseT /Ethernet
IR / RS-232
Power
UHD Display
IR Receiver

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MX-0404-H2 v2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wyrestorm MX-0404-H2 v2

  • Page 1 4x4 or 6x6 4K HDMI Matrix Switcher with HDCP 2.2 Encryption MX-0404-H2 v2 | MX-0606-H2 v2 Quickstart Guide Note: In the Box IMPORTANT! Installation Requirements • • • Recommended Products Additional Information • • • • Basic Wiring Diagram HDMI...
  • Page 2 Wiring and Connections HDMI Wiring IMPORTANT! HDMI Wiring Guidelines • • IR TX/RX Wiring IMPORTANT! IR TX/RX Guidelines IR Ext Port Pinout Tip: +5V DC • Ring: IR Signal Sleeve: Ground (GND) • • RS-232 Wiring Pin 5: GND (Ground) Pin 3: RX (Receive) Pin 2: TX (Transmit) Outside of DB9 chassis port shown.
  • Page 3 EDID Settings • • • • Copying EDIDs Front Panel, Web UI or API EDID Control FL-2 Note: SmartEDID/Front Panel/ Web UI 4K UHD 1080p Control Accessing the Web UI...
  • Page 4: Troubleshooting

    Audio and Video Inputs Outputs Audio Formats Video Resolution (Max) Color Depth Maximum Pixel Clock Communication and Control HDMI RS-232 Ethernet Front Panel Power Power Supply (Internal) Max Power Consumption Environmental Operating Temperature Storage Temperature Maximum BTU Dimensions and Weight Rack Units/Wall Box Height Width...
  • Page 5 6x6 4K UHD HDMI Matrix Switcher with HDCP 2.2 MX-0606-H2 HDMI outputs Link to Control System Settings from source • • • • • • • • • • Copyright © 2016 WyreStorm Technologies | wyrestorm.com 1 of 2 info@wyrestorm.com...
  • Page 6 Cat5/5e/6 AC Mains RS-232 to Control System HDMI to HDMI from display source HDMI from HDMI to source display UHD Source UHD Source IR Receiver UHD Display UHD Display Copyright © 2016 WyreStorm Technologies | wyrestorm.com 2 of 2 info@wyrestorm.com...
  • Page 7 Continue until the desired content source.. appears on the display device for the chosen output. Copyright © 2016 WyreStorm Technologies | wyrestorm.com North America: 518-289-1294 | EMEA/ROW: 44 (0) 1793 230 343 1 of 1 H2 Matrix Operation User Guide | 160330 support@wyrestorm.com...
  • Page 8 Web User Interface (UI) Reference Guide (v7 Matrices) Note: This document supports version 7 matrices only. See Identifying Version in the introduction section for details. Thank you for choosing this WyreStorm product. Please read these instructions carefully before installing to avoid complications later.
  • Page 9: Table Of Contents

    LAN to Serial Advanced Settings Advanced Setting Login EDID Copy iii. Signal Enforce (No Hotplug) iv. Quick Switching Mode with WyreStorm QuickSync™ Technology v. Long Cable Mode vi. IR Callback vii. Restore Matrix to Factory Settings viii. EDID Setting ix.
  • Page 10: Introduction

    Introduction In addition to control via front panel, remote handset, RS232 and RS485, models within the WyreStorm matrix range also incorporate number of inputs and outputs available. As such, this guide serves to explain the generic functionality of the interface across all matrix...
  • Page 11 Password option when logging in with a new saved password to avoid needing to restore to factory default settings if a password has been forgotten. See Password section of this guide. After logging in, the main screen will appear with three tabbed submenu headings. Technical support: support@wyrestorm.com EMEA/ROW: +44 (0) 1793 230 343...
  • Page 12: Matrix Control Window

    Matrix Control Window WyreStorm 8x8 Matrix main menu WyreStorm 16x16 Matrix main menu states are able to be saved to the matrix for loading at a later time. i. Input/Output Switch routing of an input to an output. If a routing error occurs, the slot will be highlighted red.
  • Page 13: Switch All

    Once changes have been made, click the corresponding Save 1, Save 2 or Save 3 iv. Matrix Activity Log The Log displayed by using the Show or Hide in the General Settings Tab. NOTE: The Log is displayed by default. Technical support: support@wyrestorm.com EMEA/ROW: +44 (0) 1793 230 343...
  • Page 14: General Setting

    General Settings • • • Update Web UI • • US/CAN/MEX: +1-518-289-1294 Toll Free Technical Support: +1-844-280-WYRE (9973)
  • Page 15: Change Password

    Set Static IP Address Select Static Apply to save the changes. NOTE: The matrix will reboot and the current connection to the Web UI will be lost due to the change in IP Address. Technical support: support@wyrestorm.com EMEA/ROW: +44 (0) 1793 230 343...
  • Page 16: Obtaining Ip Address Automatically

    NOTE: The matrix will reboot and the current connection to the Web UI will be lost due to the change in IP Address. address is not recognized, press back in the browser and repeat steps 1-3 above. vi. Update Web UI Visit the product page or the download section on wyrestorm.com Browse, Open and then Update vii. Show/Hide Activity log Displays (Show) or hides (Hide) the recent activity Log.
  • Page 17: Lan To Serial

    Disable - Serial commands will not be received by the matrix. Advanced Settings The Advanced Setting section is used to perform the following tasks: • Advanced Setting Login • • IR Setting • • Technical support: support@wyrestorm.com EMEA/ROW: +44 (0) 1793 230 343...
  • Page 18: Advanced Setting Login

    Advanced Setting Login (123456) or the password entered in the Advanced Setting Password NOTE: If the password has been forgotten, SmartSetGUI should be used to reset the matrix to factory default. 8x8 Matrix Advanced Settings Screen 16x16 Matrix Advanced Settings Screen ii.
  • Page 19: Signal Enforce (No Hotplug)

    Quick Switching Mode with WyreStorm QuickSync™ Technology NOTE: While QuickSync™ is compatible with a majority of modern screens, incompatibility or unreliable switching may occur with older screens/displays from some manufacturers. If compatibility issues are experienced, WyreStorm recommends setting Quick Switching Mode to OFF.
  • Page 20: Ir Callback

    vi. IR Callback IR Callback vii. Restore Matrix to Factory Settings This action will erase all previously saved data/settings – this cannot be undone and settings will need to be input again. to restore to factory settings, as illustrated below: Restoring to Factory Default Settings using SmartSetGUI Setup.
  • Page 21: Edid Setting

    NOTE: EDID cannot be read from matrix output ports not connected to a display – verify that matrix outputs are connected to displays before attempting to read EDID. Advanced Setting. EDID Setting and click Enter. Technical support: support@wyrestorm.com EMEA/ROW: +44 (0) 1793 230 343...
  • Page 22 Output port from the Select Port dropdown options, such as output port 3 in the following example: Read US/CAN/MEX: +1-518-289-1294 Toll Free Technical Support: +1-844-280-WYRE (9973)
  • Page 23: Ir Setting

    The matrix supports leading third-party control systems and learning remotes. When using these devices to control the matrix, the Depending on WyreStorm matrix model, the System Code Switch on remote handset can be changed when more than one matrix is...
  • Page 24 16x16 Matrix IR Settings Screen 8x8 Matrix IR Settings Screen Read to read the matrix system code, with the green status bar indicating read progress percentage. Once the read is complete the IR results will appear in the table below. Custom Code to 4E.
  • Page 25 Write. Technical support: support@wyrestorm.com EMEA/ROW: +44 (0) 1793 230 343...
  • Page 26: Custom Web Ui Logo

    Once the write process is complete, the system code of the matrix will be set to 4E to enable control of the matrix using the handset x. Custom Web UI Logo section. Browse Upload for the image to appear at the top of the interface. NOTE: Image format must be .PNG xi.
  • Page 27: Matrix I/O Reference Logs

    Matrix I/O Reference Logs INPUT Input Source Resolution Cable number on Input Location Source Settings & Audio Settings Number Matrix OUTPUT Output Display Resolution Cable number on Output Location Display Settings & Audio Settings Number Matrix...
  • Page 28: Notes

    Notes...
  • Page 29 WyreStorm Technical Support time. Visit wyrestorm.com for the latest information on products. 151216 Technical support: support@wyrestorm.com EMEA/ROW: +44 (0) 1793 230 343...

This manual is also suitable for:

Mx-0606-h2 v2

Table of Contents