LED Module Care and Replacement

7. LED Module Care and Replacement

Vivid 4 Module

Each Vivid 4 has 4 LED modules connected to the panel frame by screws. Each module has a single
connector that connects to the main processing unit.

LED Lot Numbers

To ensure consistent color matching and output, replace damaged or defective modules with the same
LED lot # as the others on the panel. When combining panels to create full video wall systems (rentals,
permanent installations, etc.) it is highly recommended that the LED lot #'s on each of the panels match.
LED lot #'s can be located on the back of each module.
Connector
LED LOT #
Orientation Arrow

A and B Modules

The Vivid 4 has 2 types of modules, designed to only plug in to the Service Module from one direction.
Check where the connector is when the orientation arrows are pointing up to determine whether the
module is an A type (top half, connector down) or a B type (bottom half, connector up).