Using The Minute Minder (If Fitted) - STOVES 1000DFDL User & Installation Instructions Manual

Dual fuel range cooker for natural gas models and lp gas models
Table of Contents

Advertisement

Minute Minder (if fitted)
Initial display
Time of day
Minus
Plus
button
button
button
The digital timer enables you to set the
time of day (24 hour clock) and the
minute minder alarm.
Setting the "Time of Day"
1. Switch on the electricity supply to
the appliance.
The display will flash.
2. Press and release the time of day
button.
3. Set the time of day with the plus
and minus buttons.
4. The time will be set 7 seconds after
the last plus or minus operation.
Alarm tones
After setting the time of day, you can
select one of three alarm tones.
Press the minus button to listen to the
first tone, then release the minus button
and press it again to listen to the
second tone, etc.
Releasing the minus button after a tone
has sounded will automatically select
that tone.
Setting the minute minder
1. Press and release the plus button
to change the display from clock
to minute minder - the bell symbol
will light.
2. Use the plus and minus buttons to
set the length of time before the
alarm tone will sound. The display
will increase / decrease in units of
10 seconds up to 99 minutes 50
seconds, and in units of 1 minute
from 1 hour 40 minutes upwards.
The maximum period which may
be set is 10 hours.
The display format will change
after 99 minutes and 50 seconds
to 1 hour and 40 minutes.
During countdown, the minute
minder has priority on the display,
which will show (in minutes :
seconds, or hours : minutes) the
time remaining.
When countdown is complete, the
tone will sound for 7 minutes, or it
can be reset with one touch of
any button.
To cancel the minute minder at
any other time, run down the set time
with the minus button.
The display will revert to show the
time of day.
6
Installation Instructions
Before
you
start:
Please
read
instructions. Planning your installation will
save you time and effort.
Prior to installation, ensure that the local
distribution conditions (nature of the gas and
gas pressure) and the adjustment of the
appliance are compatible. The adjustment
conditions are stated on the data badge.
This appliance is not connected to a combustion
evacuation device. It shall be installed and
connected in accordance with current
installation regulation. Particular attention
shall be given to the relevant requirements
regarding ventilation.
In your own interest and that of safety, it is
the law that all gas appliances be installed
and serviced by competent persons.
CORGI registered installers undertake to
work to satisfactory standards.
Where regulations or standards have been
revised since this handbook was printed,
always use the latest edition.
In the UK the regulations and
standards are as follows:
1. Gas
Safety
Regulations
1996
(Installation and Use).
2. Building Regulations - Issued by the
Department of the Environment.
3. Building
Standards
(Scotland)
(Consolidated) - Issued by the Scottish
Development Department.
4. The current I.E.E. Wiring Regulations.
5. Electricity at Work Regulations 1989.
6. BS 6172 Installation of Domestic Gas
cooking Appliances
Also, for LP Gas, refer to BS 5482
Part 1, Part 2 or part 3 as relevant.
7. Installation & Servicing Instructions for
this appliance.
the
For installation in countries other than the
UK, the appliance must be connected in
accordance with all local gas and electrical
regulations.
In the Republic of Ireland,
Installers should refer to IS813 Domestic
Gas Appliances.
Ventilation Requirements
The room containing the appliance should
have an air supply in accordance with
BS 5440: Part 2: 1989:
All rooms require an openable window,
or equivalent, and some rooms will
require a permanent vent as well.
For room volumes up to 5m
vent of 100cm
2
is required.
If the room has a door that opens directly
to the outside, or the room exceeds
10m
3
, NO AIR VENT is required.
For room volumes between 5m
10m
3
an air vent of 50cm
If there are other fuel burning appliances
in the same room, BS 5440: Part 2:
1989 should be consulted to determine
the air vent requirements.
This appliance must not be installed in
a bed sitting room of less than 20m
in a bathroom or shower room.
Windows and permanent vents should
therefore not be blocked or removed without
first consulting a CORGI gas installer.
LP Gas only - Do not install this appliance
in a room below ground level. This does
not preclude installation into rooms which
are basements with respect to one side of
the building, but open to ground level on
the opposite side.
In the Republic of Ireland, refer to relevant Irish
Standards for correct ventilation requirements.
Failure to install appliances correctly is
dangerous and could lead to prosecution.
15
3
an air
3
and
2
is required.
or
3