Z1 Auto
System
AUTO-ADJUSTING CONTINUOUS POSITIVE AIRWAY PRESSURE SYSTEM
User Guide
Human Design Medical, LLC
www.TheCPAPShop. com
AN AFFILIATE OF BREAS MEDICAL AB
866-414-9700
User Guide
English

Advertisement

Table of Contents
loading

Summary of Contents for Human Design Medical Z1 Auto System

  • Page 1 Z1 Auto System ™ AUTO-ADJUSTING CONTINUOUS POSITIVE AIRWAY PRESSURE SYSTEM User Guide Human Design Medical, LLC www.TheCPAPShop. com AN AFFILIATE OF BREAS MEDICAL AB 866-414-9700 User Guide English...
  • Page 2 Product Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Z1 Auto™, Z1 Unplugged™, and NiteLog™ are trademarks of Human Design Medical, LLC . The HDM logo ( ), Z1®, PowerShell®...
  • Page 3: Welcome To Your Z1 Auto System

    This User Guide will help you take advantage of the features and capabilities of this amazing portable, auto-adjusting CPAP device. Please read this User Guide carefully before using your Z1 . Owner/User Responsibility The owner/user of the Z1 Auto System is responsible for reading and understanding this User Guide. The user is responsible for any injury or damage that results from: • Operation of the Z1 other than in accordance with the operating instructions contained in the User Guide supplied .
  • Page 4: Terms Used In This User Guide

    NOTE is an informative or helpful note . Medical Information Indications for Use Your Z1 Auto System is a single patient, reusable device that provides continuous positive airway pressure (CPAP) to support treatment of adults weighing over 66 lbs (30 kg) with obstructive sleep apnea (OSA) .
  • Page 5: Z1 Warnings And Cautions

    • If you notice any unexplained changes in the performance of your Z1 or your Z1 is making unusual or harsh sounds, or if the Z1 or Power Supply are dropped or mishandled, discontinue use and contact the Human Design Medical Service Center at 1-855-436-8729 [1-855-HDMUSA9] . • If your Z1, Power Supply, PowerShell or Battery is dropped or mishandled, or if water is spilled into an enclosure, or if an enclosure is broken, discontinue use and contact the Human Design Medical Service Center at 1-855-436-8729 [1-855-HDMUSA9] .
  • Page 6 Design Medical Battery . Do not use any other AC adapters, batteries, or other power sources to power the Z1 . Do not use the Human Design Medical Power Supply, PowerShell or Battery to power any device other than the Z1 .
  • Page 7 • Your Z1 should only be used with standard or slim style CPAP air tubing as recommended by your physician, clinician or healthcare provider . • Do not leave long lengths of air tubing around the top of your bed. The tube could twist around your head or neck while you are sleeping . • Do not connect or insert any device, cable or articles into the Micro USB or Micro SD ports of your Z1 except as described in this User Guide . Connecting other devices could result in injury to you or damage to the Z1 and void the warranty .
  • Page 8: Battery Warnings And Cautions

    • Immediately discontinue use of the Battery if, while using, charging or storing the Battery, the Battery emits an unusual smell, feels hot, changes color, changes shape or appears abnormal in any other way . Contact the Human Design Medical Service Center at 1-855- 436-8729 [1-855-HDMUSA9] if any of these problems are observed .
  • Page 9: Getting To Know Your Z1 Auto System

    . • Only charge the Battery with the supplied Human Design Medical PowerShell and the supplied Human Design Medical Power Supply . Do not use any other removeable battery charger, AC adapter, or other device to charge the Battery .
  • Page 10: Z1 Auto Cpap Device

    . Always consult with your physician or healthcare provider regarding the selection of tubing for your treatment . Follow the instructions provided with the tubing . Replacement tubing can be purchased from Human Design Medical at 1-855-436-8724 [1-855-HDMUSA4] or online at www . hdmusa . c om .
  • Page 11: Initial Set Up

    Z1 to you . If you have any questions or problems as you go through the setup process, please call Human Design Medical Customer Service at 1-855-436-8729 [1-855-HDMUSA9] for assistance . Human Design Medical wants your user experience with the Z1 to be trouble and frustration free .
  • Page 12: Assembling And Powering Up

    Z1 Auto Unplugged Includes everything that comes with the Z1 Auto Base Model, plus: Battery Shuttle and Overnight Battery PowerShell Assembling and Powering Up Filter and End Cap Your Z1 comes with the first filter already installed . Replacement filters may be installed as follows: 1 .
  • Page 13: Power Supply

    WARNING: The Z1 must only be used with the optional Human Design Medical PowerShell with Human Design Medical Battery (or the Human Design Medical Power Supply) . DO NOT use any other power source Figure 6 with the Z1 .
  • Page 14: Using Your Z1 Auto

    NOTE: The Z1 can be removed from the PowerShell by pressing the two [ ] symbols on the sides of the PowerShell and sliding the Z1 out . 3 . The Z1 will power up and cycle through a series of startup displays . 4 .
  • Page 15: Function Modes

    Number of Solid Bars Charge Remaining 10-25% 25-50% 50-75% 75-100% AC Power Indicator This icon is displayed when the Z1 is connected to an AC power outlet via the Power Supply . General Status Display In Standby mode, this display field alternates between a display of the current date, the current function mode and Z-Breathe setting and the current Bluetooth status (Bluetooth on or Bluetooth off ) .
  • Page 16: Starting And Stopping Treatment

    Starting and Stopping Treatment 1 . Press the Start/Stop Button on the Z1 to initiate Current treatment using the pre-programmed prescription Treatment setting . The Treatment Pressure Display will show the Pressure actual pressure being delivered at all times . If the Ramp Mode has been programmed, the ramp start pressure Start/Stop Button...
  • Page 17: Programming Ramp Mode 1

    drops while keeping the pressure constant, thereby delivering more comfortable therapy . Pressure swings can vary between users due to lung capacity and other factors . For this reason we have created 3 levels of Z- Breathe to accomodate individual users’ preferences: —...
  • Page 18: Z1 Auto Bluetooth Connectivity

    App as well as detailed use instructions . Z1 User Software Human Design Medical provides User Software for data viewing which may be downloaded from the Human Design Medical website to any Windows computer . A separate user guide for this software is available for download at the Human Design Medical website, www .
  • Page 19: Care

    NOTE: The battery will not charge if you are using your Z1 Auto at the same time . Care The Z1 Auto System needs periodic care . It is the user’s responsibility to be aware of the following items for care: • Inspections...
  • Page 20: Reminder Alert (Air Leak Detection)

    Do not attempt to use any air filter which is not supplied by Human Design Medical for the Z1 . The Z1 is designed to only work with approved materials . A filter which is not approved may cause damage to the Z1 from overheating .
  • Page 21: Fault Conditions

    Discontinue use and contact your healthcare provider or HDM . * *Human Design Medical Service Center at 1-855-436-8729 [1-855-HDMUSA9] . USB Firmware Upgrade Z1 firmware upgrades can be downloaded via a link on support . h dmusa . c om . Complete instructions can be found on the web site .
  • Page 22 A power supply not designed for the Z1 is connected to the Z1 . Remove the power supply unit and replace with a Human Design Medical approved unit . Treatment Will Not Start Check the display for a fault condition . Refer to the Fault Codes table in “Fault Conditions”...
  • Page 23: Guidance And Manufacturer's Declaration

    Guidance and manufacturer’s declaration - electromagnetic emissions The Z1 Auto System is intended for use in the electromagnetic environment specified below . The customer or the user of the Z1 Auto System should assure that it is used in such an environment . Emissions test Compliance Electromagnetic environment —...
  • Page 24 Guidance and manufacturer’s declaration — electromagnetic immunity The Z1 Auto System is intended for use in the electromagnetic environment specified below . The customer or the user of the Z1 Auto System should assure that it is used in such an environment . Immunity test...
  • Page 25 RF transmitters, an electromagnetic site survey should be considered . If the measured field strength in the location in which the Z1 Auto System is used exceeds the applicable RF compliance level above, the Z1 Auto System should be observed to verify normal operation . If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Z1 Auto System .
  • Page 26 The Z1 Auto System is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled . The customer or the user of the Z1 Auto System can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Z1 Auto System as recommended below, according to the maximum output power of the communications equipment .
  • Page 27: Technical Specifications

    Technical Specifications 30W Power Adapter Part # HD60-6010 Unit Input range 100–240V, 50–60Hz Typical power consumption 20W (30VA) Maximum power consumption 35W (70VA) 41 º F to 95 º F (5 º C to 35 º C) Operating temperature Operating humidity 10–80% Relative Humidity, Non-Condensing Operating altitude Sea level to 8,000 ft (2,433 m)
  • Page 28 Shelf life Batteries are shipped with between 30% and 50% of rated capacity, providing a minimum of 6 months shelf life when stored at 25°C . If storage temperature exceeds 25°C over a 6-month period then shelf life will be reduced and the battery should be recharged periodically .
  • Page 29: Servicing

    Servicing The Z1 Auto System is intended to provide safe and reliable operation when operated in accordance with the instructions provided by Human Design Medical . Human Design Medical recommends that the Z1 Auto System be inspected and serviced by an authorized Human Design Medical Service Center if there is any sign of wear or concern with Z1 function .
  • Page 30: Faa Compliance

    Section 21, Category M . Human Design Medical has successfully completed testing for the Z1 Auto System . The Z1 Auto System complies with RTCA/DO-160, Section 21, Category M and can be considered FAA compliant . * Some airlines may require advance notification before travel, and devices may need to be operated by battery .
  • Page 31 This page is intentionally left blank.
  • Page 32: Product Registration

    Register your new device . Registering your device allows us to provide better customer AN AFFILIATE OF BREAS MEDICAL AB service and warranty coverage . Please register as soon as possible . Mail completed form to: HDM Product Registration About you. 200 Garrett St, Suite P Charlottesville, VA 22902 NAME:...