Human Design Medical Z1 CPAP System User Manual

Human Design Medical Z1 CPAP System User Manual

Continuous positive airway pressure system

Advertisement

Z1
CPAP System
®
CONTINUOUS POSITIVE AIRWAY PRESSURE SYSTEM
User Guide
Human Design Medical
AN AFFILIATE OF BREAS MEDICAL AB
AN AFFILIATE OF BREAS MEDICAL AB
Human Design Medical
Newton, MA 02458
®
User Guide
English
Z1 User Guide v1 03012018
#40-0007 Rev. C

Advertisement

Table of Contents
loading

Summary of Contents for Human Design Medical Z1 CPAP System

  • Page 1 CPAP System ® CONTINUOUS POSITIVE AIRWAY PRESSURE SYSTEM User Guide Human Design Medical AN AFFILIATE OF BREAS MEDICAL AB AN AFFILIATE OF BREAS MEDICAL AB Human Design Medical Newton, MA 02458 ® User Guide English Z1 User Guide v1 03012018...
  • Page 2: Table Of Contents

    Product Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Z1®, the HDM logo ( ), PowerShell®, NiteLog® and Z-Breathe® are registered trademarks of Human Design Medical .
  • Page 3: Welcome To Your Z1 Cpap System

    Indications for Use • Air Travel – The Z1 adjusts to an airplane’s cabin pressure and is approved for use on Your Z1 CPAP System is a single user, reusable device that provides continuous positive airway airplanes . pressure (CPAP) to support treatment of adults weighing over 66 lbs (30 kg) with obstructive sleep •...
  • Page 4: Z1 Warnings And Cautions

    Medical Battery . Do not use any other AC adapters, batteries, or other power sources • In the event of a power failure or machine malfunction, remove the mask to power the Z1 . Do not use the Human Design Medical Power Supply, PowerShell or immediately .
  • Page 5: Battery Warnings And Cautions

    Accumulation of filtered particles over time can reduce the efficiency and shorten the abnormal in any other way . Contact the Human Design Medical Service Center at 1-855- life of any CPAP device, including the Z1 . Replacement filters are available at your retail 436-8724 if any of these problems are observed .
  • Page 6: Getting To Know Your Z1 Cpap System

    . CPAP Tube Getting to Know Your Z1 CPAP System The Z1 System is provided with a 4 ft slim style CPAP Tube . The CPAP Tube connects the Z1 to your mask . Always consult with your physician or health care provider regarding the selection of tubing Package Contents for your treatment .
  • Page 7: Set Up Guide

    Z1 to you . If you have any 3 . Ensure all connections are tight to avoid air leaks . questions or problems as you go through the setup process, please call Human Design Medical (Figure 3) Customer Service at 1-855-436-8724 for assistance .
  • Page 8: Using Your Z1

    Using Your Z1 PowerShell and Battery (Available Separately) WARNING: The Z1 must only be used LCD Display with the optional Human Design Medical PowerShell with Human Design Medical General Status Display Battery Status Display (PowerShell Only) Battery (or the Human Design Medical Power Supply) .
  • Page 9: Starting And Stopping Treatment

    Choosing Between Z-Breathe settings General Status Display ® In Standby Mode, this display field alternates between a display of the current date, the current The Z-Breathe setting of 1-3 is indicated by the number following Z-Breathe Setting function mode and the Z-Breathe setting . During treatment and while setting treatment the CPAP designation on the LCD screen .
  • Page 10: User Software

    . Contact your retail medical supplier or at www . h dmusa . c om for replacement parts . software is available for download at the Human Design Medical website, www . h dmusa . c om . This software can be used to upgrade the Z1 firmware as new releases are made available .
  • Page 11: Reminder Alert (Air Leak Detection)

    Do not attempt to use any air filter which is not supplied *Human Design Medical Service Center at 1-855-436-8724 . by Human Design Medical for the Z1 . The Z1 is designed to only work with approved materials . A filter which is not approved may cause damage to USB Firmware Upgrade the Z1 from overheating .
  • Page 12: Guidance And Manufacturer's Declaration

    Guidance and manufacturer’s declaration - electromagnetic emissions treatment and adjust ramp time . The Z1 CPAP System is intended for use in the electromagnetic environment specified below . The CPAP Tube is blocked, pinched or punctured . customer or the user of the Z1 System should assure that it is used in such an environment .
  • Page 13 RF transmitters, an electromagnetic site survey should be considered . If the measured field strength in the location in which the Z1 CPAP commercial or hospital System is used exceeds the applicable RF compliance level above, the Z1 CPAP System should be observed to verify normal operation . If abnormal environment .
  • Page 14: Technical Specifications

    The Z1 CPAP System is intended for use in an electromagnetic environment in which radiated RF Unit Input range 100–240V, 50–60Hz disturbances are controlled . The customer or the user of the Z1 CPAP System can help prevent Typical power consumption 20W (30VA)
  • Page 15: Servicing

    Human Design Medical . Human Design Medical recommends Z-Breathe Setting Treatment Pressure Operating Time that the Z1 System be inspected and serviced by an authorized Human Design Medical Service 20 cmH 8 . 9 hours Center if there is any sign of wear or concern with Z1 function .
  • Page 16: Contact Information

    . h dmusa . c om Main phone (customer service): 1-855-436-8724 Service support or warranty coverage: 1-855-436-8724 Email: hdmsupport@hdmusa . c om Human Design Medical / Breas • 57 Chapel Street Suite 200 • Newton, MA 02458 • 1-855-436-8724...
  • Page 17: Product Registration

    Registering your device allows us to provide better customer service and warranty coverage . Please register as soon as possible . Mail completed form to: HDM Product Registration About you. Human Design Medical/ Breas 57 Chapel Street, Suite 200 NAME: Newton, MA 02458 First...
  • Page 18 This page is intentionally left blank.