6-4. EHSE-MECR1.UK, ERSE-MECR1.UK
CNPWM
(WH)
1
3
3
CNP1
TBO.1
(WH)
1
1
M
1~
2
MP1
3
M
3
1~
M
2WV2b
1~
4
MP2
5
M
1~
6
MP3
1
3
CNP4
(RD)
TBO.2
Close
1
M
N
Open
2
1~
3
MXV
1
4
3
*1
5
5
6
CNV1
(WH)
TBO.3
1
Signal output
(Boiler)
2
3
Signal output
(Error)
4
5
Signal output
(Defrost)
6
Signal output
7
(Comp. ON)
8
TBO.4
1
CNIH
M
(OG)
2
2WV2a
3
1
4
3
5
Signal output
(Cooling)
6
1
3
CNBHT
(BK)
CNBC
(GY)
1
3
1
3
5
7
CNBH
(WH)
Table 1 Signal Inputs
Name Terminal block Connector
Item
Room thermostat 1
IN1
TBI.1 13-14
input
IN2
TBI.1 11-12
Flow switch 1 input
Flow switch 2 input
IN3
TBI.1 9-10
(Zone1)
IN4
TBI.1 7-8
Demand control input Normal
Outdoor thermostat
IN5
TBI.1 5-6
input *1
Room thermostat 2
IN6
TBI.1 3-4
input
Flow switch 3 input
IN7
TBI.1 1-2
(Zone2)
Electric energy meter
IN8
TBI.3 1-2
1
Electric energy meter
IN9
TBI.3 3-4
2
IN10
TBI.3 5-6
Heat meter
IN1A TBI.3 12-14 CN1A Flow sensor
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the
heaters and related parts may be reduced.
*2. To turn on the boiler operation, use the main remote controller to select "Boiler" in
"External input setting" screen in the service menu.
Symbol
Name
TB1
Terminal block <Power supply, Outdoor unit>
MP1
Water circulation pump 1
(Space heating/cooling & DHW)
MP2
Water circulation pump 2
(Space heating/cooling for Zone1)(Local supply)
MP3
Water circulation pump 3
(Space heating/cooling for Zone2)(Local supply)
3WV(2WV1) 3-way valve (2-way valve 1)(Local supply)
2WV2a
2-way valve (For Zone 1)(Local supply)
2WV2b
2-way valve (For Zone 2)(Local supply)
MXV
Mixing valve (Local supply)
TH1
Thermistor (Room temp.)(Option)
TH2
Thermistor (Ref. liquid temp.)
THW1
Thermistor (Flow water temp.)
THW2
Thermistor (Return water temp.)
THW5
Thermistor (DHW tank water temp.)(Option)
OCH590B
<How to use TBO.1 to 4>
1
Connect them using either way as shown below.
2
4
F1
6
Tool
CN01
F2
(WH)
Conductor
X1
Outline view
X2
X3
1
TBO.1
2
X14
3
1
CNP1
(WH)
4
3
5
6
1
1
CNP4
TBO.2
1
3
(RD)
2
X5A
SW5
3
4
8
5
X5B
6
1
1
X4
CNV1
TBO.3
3
1
SW4
(WH)
5
2
6
3
1
4
5
SW3
6
7
X10
8
8
1
X11
TBO.4
1
2
SW2
3
X12
4
8
5
1
X15
1
6
CNIH
(OG)
3
SW1
1
1
CNBC
CNBHT
8
X13
(GY)
(BK)
3
3
X9
1
CNBH
X8
(WH)
7
CN1A
(WH)
1
4
2 4 6 8 10 12 14
2 4 6 8 10 12 14
1 3 5 7 9 11 13
1 3 5 7 9 11 13
TBI.1
TBI.3
X6
X7
TBI.1
1
2
3
4
1
2
1
4
1
3
1
2
t
t
t
t
t
°
°
°
°
°
OFF (Open)
ON (Short)
Refer to SW2-1 in "6-5. DIP switch setting".
Refer to SW2-2 in "6-5. DIP switch setting".
Refer to SW3-2 in "6-5. DIP switch setting".
Heat source OFF/
Boiler operation *2
Heater operation/
Standard operation
Boiler operation *2
Refer to SW3-1 in "6-5. DIP switch setting".
Refer to SW3-3 in "6-5. DIP switch setting".
Refer to installation manual.
Symbol
THW6
Thermistor (Zone1 flow temp.)(Option)
THW7
Thermistor (Zone1 return temp.)(Option)
THW8
Thermistor (Zone2 flow temp.)(Option)
THW9
Thermistor (Zone2 return temp.)(Option)
THWB1
Thermistor (Boiler flow temp.)(Option)
THWB2
Thermistor (Boiler return temp.)(Option)
IN1
Room thermostat 1 (Local supply)
IN2
Flow switch 1 (Local supply)
IN3
Flow switch 2 (Local supply)
IN4
Demand control (Local supply)
IN5
Outdoor thermostat (Local supply)
IN6
Room thermostat 2 (Local supply)
IN7
Flow switch 3 (Local supply)
IN8
Electric energy meter 1 (Local supply)
IN9
Electric energy meter 2 (Local supply)
Indoor unit powered
via outdoor unit
To outdoor
unit
Tool
L
N
S1
S2
S3
TB1
Conductor
Top view
BK
1
BK
2
CN01
(WH)
4
1
6
2
CN01
(WH)
4
F2
F1
6
IEC T6.3AL250V
IEC T10AL250V
1
CN3C
BN
(BU)
1
3
CN3C
LED1
OG
(BU)
3
1
CNPWM
(WH)
3
CNRF
Wireless receiver
(WH)
(Option)
LED2
CN105
WiFi adapter
(RD)
(Option)
LED3
CNIT
(BU)
1
CN22
(BU)
2
CN108
LED4
CNW5
CNW12
CN21
CN20
*1
(WH)
(RD)
(YE)
(RD)
1
1
1
1
3WV
2
2
3
4
4 5 6
TBO.2
TBO.2
2
4
6
8
10
12
M
1
3
5
7
9
11
13
1~
TBI.2
3WV
TBI.3
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
+
+
+
CN1A
(WH)
1
Table 2 Outputs
Name Terminal block Connector
Water circulation pump 1 output (Space heat-
OUT1
TBO.1 1-2 CNP1
ing/cooling & DHW)
Water circulation pump 2 output (Space heat-
OUT2
TBO.1 3-4
ing/cooling for Zone1)
Water circulation pump 3 output (Space heat-
ing/cooling for Zone2) *1
OUT3
TBO.1 5-6
2-way valve 2b output *2
OUT4
TBO.2 4-6 CNV1 3-way valve (2-way valve) output
TBO.2 1-2
OUT5
Mixing valve output *1
TBO.2 2-3
OUT6
CNBH 1-3 Booster heater 1 output
OUT7
CNBH 5-7 Booster heater 2 output
OUT8
TBO.4 5-6
Cooling signal output
OUT9
TBO.4 3-4 CNIH Immersion heater output
OUT10 TBO.3 1-2
Boiler output
OUT11 TBO.3 3-4
Error output
OUT12 TBO.3 5-6
Defrost output
OUT13 TBO.4 1-2
2-way valve 2a output *2
OUT14
CNP4 Water circulation pump 4 output (DHW)
OUT15 TBO.3 7-8
Comp. ON signal
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1. For 2-zone temperature control.
*2. For 2-zone valve ON/OFF control.
Name
IN10
IN1A
FLOW TEMP. CONTROLLER (FTC5)
14
Indoor unit powered
by independent source
Power supply
To outdoor
unit
~/N 230V 50Hz
L
N
S1
S2
S3
TB1
BK
BK
1
2
CN01
4
(WH)
6
BN
1
CN3C
OG
(BU)
3
1. Symbols used in wiring diagram are,
connector,
: terminal block.
2. Indoor unit and outdoor unit connecting wires
have polarities, make sure to match terminal
numbers (S1, S2, S3) for correct wirings.
3. Since the outdoor unit side electric wiring may
change, be sure to check the outdoor unit
electric wiring diagram for service.
2WV1
4 5 6
M
1~
2WV1
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
CN22
(BU)
4
1
2
t
°
t
°
t
°
t
°
t
°
t
°
Item
Symbol
Name
Heat meter (Local supply)
Flow sensor
TBO.1−4 Terminal block <Outputs>
TBI.1−3 Terminal block <Signal Inputs, Thermistor>
F1
Fuse (IEC T10AL250V)
F2
Fuse (IEC T6.3AL250V)
SW1−5 DIP switch
"6-5. DIP switch setting".)
(See
X1−15
Relay
LED1
Power supply (FTC5)
LED2
Power supply (Main remote controller)
LED3
Communication (FTC5-Outdoor unit)
LED4
Reading or writing data to SD card
CNPWM Pump speed control signal for MP1
CN108
SD card connector
:
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Heating
DHW
Close
Stop
Open
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Normal
Error
Normal Defrost
OFF
ON
OFF
ON
OFF
ON