Option Part Numbers - Siemens SINAMICS DCM Operating Instructions Manual

Base drive panel instructions – v 1.0 extended range: 1500a - 2800a dc 575v, 690v, 830v & 950v 3-phase ac rated armature supply
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

3.3 Option part numbers

Options
Standard CUD coated in right slot (Possible with Advanced CUD in left)
4
Standard CUD
4
Advance CUD coated in right slot (Possible with Advanced CUD in left)
4
Advance CUD
4
AOP30 - Advance Operator Panel
RS485 connecting cable for connecting the AOP30 to one CUD; 3m
RS485 connecting cable for connecting the AOP30 to two CUDs; 3m
SMC10 - Sensor Module Cabinet-Mounted – Resolver
3
SMC30 - Sensor Module Cabinet-Mounted – Incremental Encoder
1
CBE20 coated left – PROFINET, EtherNet/IP (Possible with Advanced CUD in left)
CBE20 coated right – PROFINET, EtherNet/IP (Possible with Advanced CUD in right)
TM15 - Terminal Module
TM31 - Terminal Module
TM150 - Terminal Module
TMC - Terminal Module Cabinet – G63 option (C98043-A7125-L1)
2
1
A pulse encoder evaluation circuit is a standard component of the basic SINAMICS DCM DC Converter. The SMC30 only needs
to be ordered in configurations requiring evaluation of a second pulse encoder.
2
To equip two CUDs with one TMC each, option G63 must be ordered twice.
3
Only SMC10 devices with Part # 6SL30550AA005AA3 (slim construction) are supported.
Older SMC10 devices may not be used!
An Advanced CUD must be installed to connect the SMC10. The Standard CUD does not have Drive-Cliq connectors.
Firmware version V1.4 SP1 HF3 or higher is required. If an older Firmware is loaded in the drive and the SMC10 is connected,
the drive will generate fault F01360 – "Topology: Actual topology invalid" with fault value 8 during startup and the drive won't
be operational.
Standard CUD and Advanced CUD parts are meant to be replacements (spare or upgrade) for the CUD supplied with the
4
Converter. The CUD boards do not include the mounting screws, studs and connector board.
To upgrade the drive with an additional CUD, the customer will need to purchase both the spare CUD and the connector board
(the connector board comes with all of the screws and studs to mount the CUD in the drive) or a CUD Kit which bundles both
the CUD and connector board at a reasonable cost – reference Section 3.4 CUD Kits below.
Order No.
6RY18030AA200AA1
6RY18030AA000AA1
6RY18030AA250AA1
6RY18030AA050AA1
6SL30550AA004CA5
6RY18070AP00
6RY18070AP10
6SL30550AA005AA3
6SL30550AA005CA2
6SL30550AA002EB0
6SL30550AA002EB0
6SL30550AA003FA0
6SL30550AA003AA1
6SL30550AA003LA0
6RY18030AB05
Parts and service
3.3 Option part numbers
3-3

Advertisement

Table of Contents
loading