Electrical Connection
The heater must be installed in accordance with the country / regional
requirements & regulations. In any event the work must be carried out by
a qualified electrician, who will provide a certificate of conformity upon
completion of the work.
Power Requirements
All B-100 heaters are fitted with their own specification plaque that
details the power requirements for the heater. Below is a table of power
requirements for the most common voltages - if your voltage is not listed
please refer to the specification plaque on the heater.
The below table also shows the number of banks of heating elements
within your heater, each bank of elements is supplied by two
independent contactors.
Model
30-kW
36-kW
45-kW
54-kW
60-kW
72-kW
230V 3 Phase
30-kW 76-Amp
36-kW 91-Amp
45-kW 113-Amp
54-kW 136-Amp
N/A
N/A
www.elecro.co.uk
400V 3 Phase
30-kW 44-Amp
36-kW 52Amp
45-kW 66-Amp
54-kW 78-Amp
60-kW 87-Amp
72-kW 104-Amp
No of Banks
2
2
3
3
3
3
4