User's Guide
Digital-pH-Meter
PCE Instruments France EURL
76, Rue de la Plaine des Bouchers
67100 Strasbourg
France
Tel: +33 (0) 972 3537 17
Fax: +33 (0) 972 3537 18
info@pce-france.fr
www.pce-instruments.com/french
WEEE-Reg.-Nr. DE 93889386

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GPH 114 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GREISINGER GPH 114

  • Page 1 PCE Instruments France EURL 76, Rue de la Plaine des Bouchers 67100 Strasbourg France Tel: +33 (0) 972 3537 17 Fax: +33 (0) 972 3537 18 info@pce-france.fr www.pce-instruments.com/french User’s Guide Digital-pH-Meter  Please carefully read these instructions before use!  Please consider the safety instructions! ...
  • Page 2: Intended Use

    User’s guide GPH 114 H75.0.01.6C-02 Page 2 of 8 Contents GENERAL NOTE ..............................2 SAFETY ..................................2 ............................... 2 NTENDED ..........................3 AFETY SIGNS AND SYMBOLS .............................. 3 AFETY GUIDELINES PRODUCT SPECIFICATION ..........................4 ..............................4 COPE OF SUPPLY ......................4 PERATION AND MAINTENANCE ADVICE PH-ELECTRODE ..............................
  • Page 3: Safety Guidelines

    User’s guide GPH 114 H75.0.01.6C-02 Page 3 of 8 2.2 Safety signs and symbols Warnings are labeled in this document with the followings signs: Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance.
  • Page 4: Further Information

    User’s guide GPH 114 H75.0.01.6C-02 Page 4 of 8 Product Specification 3.1 Scope of supply GPH 114 with 9V battery GE 114 pH- electrode with storage bottle Operating manual 3.2 Operation and maintenance advice 1. Battery operation: If ‘bAt’ is shown in the lower display the battery has been used up and needs to be replaced. However, the device will operate correctly for a certain time.
  • Page 5: S Election Of Electrodes

    User’s guide GPH 114 H75.0.01.6C-02 Page 5 of 8 Problems may also occur when taking measurements in low-ion media containing solvent. Some of the problems occurring when taking measurements in such media can be counteracted by using a double- chamber electrode (Type GE 103) with suitable bridging electrolyte (type depending on application).
  • Page 6: C Alibration Of P H-M Eters

    0 to 90°C): 1 graduation mark = approx.10°C. Place GPH 114 meter on a solid surface; if possible try to avoid holding the meter in your hand during calibration (please refer to “Points to be observed during measuring”).
  • Page 7: Points To Be Observed During Measuring

    User’s guide GPH 114 H75.0.01.6C-02 Page 7 of 8 6 Points to be observed during measuring The electrode is equipped with a storage bottle. The bottle has to be pulled off before measuring. Then it is best to rinse the electrode with tap water.
  • Page 8: Notes A: Temperature Influence On Ph Buffer Solutions

    User’s guide GPH 114 H75.0.01.6C-02 Page 8 of 8 9 Notes A: Temperature influence on pH buffer solutions GPH buffer capsules for 100 ml buffer solution Capsules for do-it-yourself mixing – unopened capsules can be stored a long time (approx. 3 years) T [°C]...