Boiler Connections
Boiler Connections
Installation Examples
Boiler with optional low water cut-off (boiler-mounted, factory supplied)
support for piping /
component
Venting Connection
CAUTION
Under certain climatic conditions some building materials may be affected by flue products expelled in close proximity to
unprotected surfaces. Sealing or shielding of the exposed surfaces with a corrosion resistant material (e.g. aluminum
sheeting) may be required to prevent staining or deterioration. The protective material should be attached and sealed (if
necessary) to the building before attaching the vent termination. It is strongly recommended to install the vent termination
on the leeward side of the building.
34
(continued)
Vitodens 200, WB2-44/60
Viessmann offers an optional boiler
mounted low water cut-off (LWCO)
connection kit, Part No.: 7134609.
WARNING
These fittings are not designed to
support any accessories installed.
Legend
Air vent
Air bleed valve
Rubber grommet
Boiler heat exchanger connection
Extension adaptor
Adaptor, G ¾" to NPTM ¾"
Gasket, ¾"
For detailed installation information and
specific venting requirements,
reference the Vitodens 200 Venting
System Installation Instructions
supplied with the boiler.
Installation Instructions
Vitodens 200 Venting
System