For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment where the bottom of the
vent terminal and the air intake is installed above four feet above grade the following requirements must be satisfied:
1. If there is not one already present, on each floor level where there are bedroom(s), a carbon monoxide detector
and alarm shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply
with NFPA 720 (2005 Edition).
2. A carbon monoxide detector shall:
a. Be located in the room that houses the appliance or equipment;
b. Be either hard-wired or battery powered or both; and
c. Shall comply with NFPA 720 (2005 Edition).
3. A product-approved vent terminal must be used, and if applicable, a product-approved air intake must be used.
Installation shall be in strict compliance with the manufacturer's instructions. A copy of the installation
instructions shall remain with the appliance or equipment at the completion of the installation.
6
Working on the equipment
The installation, adjustment, service,
and maintenance of this boiler must be
done by a licensed professional heating
contractor who is qualified and
experienced in the installation, service,
and maintenance of hot water boilers.
There are no user serviceable parts on
the boiler, burners, or control.
Ensure main power supply to
equipment, the heating system, and all
external controls has been deactivated.
Close main gas supply valve. Take
precautions in all instances to avoid
accidental activation of power during
service work.
Technical literature
Literature for the Vitodens boiler:
- Technical Data Manual
- Installation Instructions
- Start-up/Service Instructions
- Operating Instructions
and User's Information Manual
- System Design Guidelines
- Instructions of other Viessmann
products utilized and installed
- Installation codes mentioned
in this manual
(continued)
The completeness and functionality of
field supplied electrical controls and
components must be verified by the
heating contractor. These include low
water cut-offs, flow switches (if used),
staging controls, pumps, motorized
valves, air vents, thermostats, etc.
Leave all literature at the installation
site and advise the system
operator/ultimate owner where the
literature can be found. Contact
Viessmann for additional copies.
This product comes with several
safety instruction labels attached.
Do not remove!
Contact Viessmann immediately if
replacement labels are required.