Overview of the heating engineer parameters
Line
Function
General / service
Basic diagrams
100
Selection of the basic diagram
0
No basic diagram selected
1...99.998
Basic diagrams
To adopt the selected diagram number, press the + / - buttons simul-
taneously for 3 s
Configuration
Partial diagrams
120
Selection of partial diagram oil- / gas-fired boiler
0
Partial diagram inactive (OeG0)
1...9
Partial diagrams OeG1 through OeG9
121
Selection of partial diagram solar collectors
0
Partial diagram inactive (OeG0)
1...16
Partial diagrams Sol1 through Sol16
122
Selection of partial diagram wood-fired boiler
0
Partial diagram inactive (Ho0)
1...5
Partial diagrams Ho1 through Ho5
123
Selection of partial diagram heat pump
0
Partial diagram inactive (Wp0)
Partial diagrams
1...5
124
Display of partial diagram buffer storage tank
0
Partial diagram inactive (Sp0)
1...3
Partial diagrams Sp1 through Sp3
125
Display of partial diagram d.h.w. storage tank
0
Partial diagram inactive (BwSp0)
1...10
Partial diagrams BwSp1 through BwSp10
126
Selection of partical diagram combi storage tank
0
Partial diagram inactive (KoSp0)
1...6
Partial diagrams KoSp1 through KoSp6
127
Selection of partial diagram heating circuit
0
Partial diagram inactive (Rh0)
1...3
Partial diagrams Rh1 through Rh3
Hiding sensors that are not required
130
Source outside sensor
0
Signal via bus (PPS or LPB)
1
Signal via terminal
st
131
Reduction 1
d.h.w. sensor B3
0
Without sensor B3
1
With sensor B3
nd
132
Reduction 2
d.h.w. sensor B31
0
Without sensor B31
1
With sensor B31
nd
133
Reduction 2
buffer storage tank sensor B41
0
Without sensor B41
1
With sensor B41
135
Reduction wood-fired boiler return sensor B72
0
Without sensor B72
1
With sensor B72
136
Reduction heat pump flow sensor B21
0
Without sensor B21
1
With sensor B21
137
Reduction heat pump return sensor B71
0
Without sensor B71
1
With sensor B71
138
Reduction water / brine sensor B11
0
Without sensor B11
1
With sensor B11
Siemens Building Technologies / HVAC Products
Wp1 through Wp5
Range
Unit
0...99.998
0...9
0...16
0...5
0...5
0...3
0...10
0...6
0...3
0 / 1
0 / 1
0 / 1
0 / 1
0 / 1
0 / 1
0 / 1
0 / 1
74 319 0312 0 a
Resolution
Factory
setting
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
......
0
19.08.2002