The power cable to the bias injector is supervised and an alarm is generated if
the cable is not connected. The alarm is transmitted on the IOM bus.
3
Interface
3.1
Signal and Power Interface
Table 1
Nominal input voltage
Input voltage range
Non-destructive voltage
Maximum input power
Table 2
Voltage per output (1 – 6)
Current per output
(1)
3.2
Operator Interface
The TMA-CM has the following external interfaces:
•
•
•
Indicators
The TMA-CM has eight indicators on the front panel that shows the status of
each TMA and the status of the TMA-CM.
The indicators Fault and Operational indicate the status of the TMA-CM only,
not the status of the TMAs.
Input data
Output data
Tolerance ±1.0 V at TMA current 0 − 300 mA.
Tolerance ±1.5 V at TMA current 300 − 500 mA.
Power in (+24 V DC)
IOM bus
TMA power connector
+24 V DC
+20.0 – 29.5 V DC
0 – +32 V DC
60 W
(1)
+15 V DC
Maximum 500 mA
EN/LZT 720
5(6)
0250
R1A